Papers
Topics
Authors
Recent
Assistant
AI Research Assistant
Well-researched responses based on relevant abstracts and paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses.
Gemini 2.5 Flash
Gemini 2.5 Flash 63 tok/s
Gemini 2.5 Pro 44 tok/s Pro
GPT-5 Medium 31 tok/s Pro
GPT-5 High 32 tok/s Pro
GPT-4o 86 tok/s Pro
Kimi K2 194 tok/s Pro
GPT OSS 120B 445 tok/s Pro
Claude Sonnet 4.5 35 tok/s Pro
2000 character limit reached

Experimental demonstration of spectral linear dark field control at NASA's high contrast imaging testbeds (2309.17449v1)

Published 29 Sep 2023 in astro-ph.IM

Abstract: Due to the low flux of exoEarths, long exposure times are required to spectrally characterize them. During these long exposures, the contrast in the dark hole will degrade as the the optical system drifts from its initial DH state. To prevent such contrast drift, a wavefront sensing and control (WFSC) algorithm running in parallel to the science acquisition can stabilize the contrast. However, pairwise probing (PWP) cannot be reused to efficiently stabilize the contrast since it relies on strong temporal modulation of the intensity in the image plane, which would interrupt the science acquisition. The use of small amplitude probes has been demonstrated but requires multiple measurements from each science sub-band to converge. Conversely, spectral linear dark field control (LDFC) takes advantage of the linear relationship between the change in intensity of the post-coronagraph out-of-band image and small changes in wavefront in the science band to preserve the DH region during science exposures. In this paper, we show experimental results that demonstrate spectral LDFC stabilizes the contrast to levels of a few $10{-9}$ on a Lyot coronagraph testbed which is housed in a vacuum chamber. Promising results show that spectral LDFC is able to correct for disturbances that degrade the contrast by more than 100$\times$. To our knowledge, this is the first experimental demonstration of spectral LDFC and the first demonstration of spatial or spectral LDFC on a vacuum coronagraph testbed and at contrast levels less than $10{-8}$.

Summary

We haven't generated a summary for this paper yet.

Lightbulb Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.