Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 84 tok/s
Gemini 2.5 Pro 48 tok/s Pro
GPT-5 Medium 21 tok/s Pro
GPT-5 High 28 tok/s Pro
GPT-4o 96 tok/s Pro
GPT OSS 120B 462 tok/s Pro
Kimi K2 189 tok/s Pro
2000 character limit reached

On the calibration of Astigmatism particle tracking velocimetryfor suspensions of different volume fractions (2010.11843v1)

Published 22 Oct 2020 in physics.flu-dyn

Abstract: In the present study we demonstrate for the first time how Astigmatism Particle Tracking Velocimetry (APTV) can be utilized to measure suspensions dynamics. Measurements were successfully performed in monodisperse, refractive index matched suspensions of up to a volume fraction of $\Phi=19.9\%$. For this, a small percentage of the particles is labeled with fluorescent dye acting as tracers for the particle tracking procedure. Calibration results show, that a slight deviation of the refractive index of liquid and particles leads to a strong shape change of the calibration curve with respect to the unladen case. This effect becomes more severe along the channel height. To compensate the shape change of the calibration curves the interpolation technique developed by Brockmann et al. (Experiments in Fluids, 61(2), 67, \citeyear{brockmann2020utilizing}) is adapted. Using this technique, the interpolation procedure is applied to suspensions with 6 different volume fractions ranging from $\Phi<0.01\%$ to $\Phi=19.9\%$. To determine the effect of volume fraction on the perfomance of the method, the depth reconstruction error $\sigma_z$ and the measurement volume depth $\Delta z$, obtained in different calibration measurements, are estimated. Here, a relative position reconstruction accuracy of $\sigma_z$/$\Delta z$=0.90\% and $\sigma_z$/$\Delta z$=2.53\% is achieved for labeled calibration particles in dilute ($\Phi<0.01\%$) and semi-dilute ($\Phi\approx19.9\%$) suspensions, respectively. The measurement technique is validated for a laminar flow in a straight rectangular channel with a cross-sectional area of 2.55$\times$30\,mm$2$. Uncertainties of 1.39\% and 3.34\% for the in-plane and 9.04\% and 22.57\% for the out-of-plane velocity with respect to the maximum streamwise velocity are achieved, at solid volume fractions of $\Phi<0.01\%$ and $\Phi=19.9\%$, respectively.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

We haven't generated a summary for this paper yet.

Ai Generate Text Spark Streamline Icon: https://streamlinehq.com

Paper Prompts

Sign up for free to create and run prompts on this paper using GPT-5.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-up Questions

We haven't generated follow-up questions for this paper yet.