The optimum mix of storage and backup in a highly renewable, highly reliable European electricity grid
Abstract: We estimate the variability of solar and wind energy generation potential in Europe over a 43 year period between 1980-2022 with the MERRA-2 reanalysis datasets. We compare the estimated supply potential to hourly demand data from 36 European countries to calculate the reliability of a highly renewable electricity grid in Europe. We find that in cost-optimised scenarios with onshore wind, solar and storage, but no natural gas, reliably meeting the last 1% of demand represents 36% of the entire system cost. Including small amounts of dispatchable natural gas drastically reduces the cost of a renewable, highly reliable grid: overall system costs fall by 31% when just 1% of total generation is permitted to come from natural gas. Large renewable overbuild factors (greater than $\times$4 peak demand) are required to meet modern grid reliability standards in all scenarios, and wind, rather than solar, dominates the generation mix.
Paper Prompts
Sign up for free to create and run prompts on this paper using GPT-5.
Top Community Prompts
Collections
Sign up for free to add this paper to one or more collections.