Papers
Topics
Authors
Recent
Assistant
AI Research Assistant
Well-researched responses based on relevant abstracts and paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses.
Gemini 2.5 Flash
Gemini 2.5 Flash 70 tok/s
Gemini 2.5 Pro 48 tok/s Pro
GPT-5 Medium 27 tok/s Pro
GPT-5 High 24 tok/s Pro
GPT-4o 75 tok/s Pro
Kimi K2 175 tok/s Pro
GPT OSS 120B 447 tok/s Pro
Claude Sonnet 4 36 tok/s Pro
2000 character limit reached

Correcting systematic polarization effects in Keck LRISp spectropolarimetry to <0.05% (1505.03916v1)

Published 14 May 2015 in astro-ph.IM

Abstract: Spectropolarimetric measurements at moderate spectral resolutions are effective tracers of stellar magnetic fields and circumstellar environments when signal to noise ratios (SNRs) above 2000 can be achieved. The LRISp spectropolarimeter is capable of achieving these SNRs on faint targets with the 10m aperture of the Keck telescope, provided several instrumental artifacts can be suppressed. We describe here several methods to overcome instrumental error sources that are required to achieve these high SNRs on LRISp. We explore high SNR techniques such as defocusing and slit-stepping during integration with high spectral and spatial oversampling. We find that the instrument flexure and interference fringes introduced by the achromatic retarders create artificial signals at 0.5\% levels in the red channel which mimic real stellar signals and limit the sensitivity and calibration stability of LRISp. Careful spectral extraction and data filtering algorithms can remove these error sources. For faint targets and long exposures, cosmic ray hits are frequent and present a major limitation to the upgraded deep depletion red-channel CCD. These must be corrected to the same high SNR levels, requiring careful spectral extraction using iterative filtering algorithms. We demonstrate here characterization of these sources of instrumental polarization artifacts and present several methods used to successfully overcome these limitations. We have measured the linear to circular cross-talk and find it to be roughly 5\%, consistent with the known instrument limitations. We show spectropolarimetric signals on brown dwarfs are clearly detectable at 0.2\% amplitudes with sensitivities better than 0.05\% at full spectral sampling in atomic and molecular bands. Future LRISp users can perform high sensitivity observations with high quality calibration when following the described algorithms.

Summary

We haven't generated a summary for this paper yet.

Lightbulb Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.