Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 45 tok/s
Gemini 2.5 Pro 52 tok/s Pro
GPT-5 Medium 30 tok/s Pro
GPT-5 High 24 tok/s Pro
GPT-4o 96 tok/s Pro
Kimi K2 206 tok/s Pro
GPT OSS 120B 457 tok/s Pro
Claude Sonnet 4 36 tok/s Pro
2000 character limit reached

A MeerKAT Polarization Survey of Southern Calibration Sources (2405.04131v1)

Published 7 May 2024 in astro-ph.GA and astro-ph.IM

Abstract: We report on full-Stokes L-band observations of 98 MeerKAT calibration sources. Linear polarization is detected in 71 objects above a fractional level of 0.2\%. We identify ten sources with strong fractional linear polarization and low Faraday Rotation Measure that could be suitable for wide-band absolute polarization calibration. We detect significant circular polarization from 24\% of the sample down to a detection level of 0.07\%. Circularly polarized emission is seen only for flat spectrum sources $\alpha > -0.5$. We compare our polarized intensities and Faraday Synthesis results to data from the NVSS at 1400\,MHz and the ATCA SPASS survey at 2300\,MHz. NVSS data exists for 54 of our sources and SPASS data for 20 sources. The percent polarization and Rotation Measures from both surveys agree well with our results. The residual instrumental linear polarization for these observations is measured at 0.16\% and the residual instrumental circular polarization is measured at 0.05\%. These levels may reflect either instabilities in the relative bandpass between the two polarization channels with either time or antenna orientation, or atmospheric/ionospheric variations with pointing direction. Tracking of the hourly gain solutions on J0408-6545 after transfer of the primary gain solutions suggests a deterioration of the gain stability by a factor of several starting about two hours after sunrise. This suggests that observing during the nighttime could dramatically improve the precision of polarization calibration.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-Up Questions

We haven't generated follow-up questions for this paper yet.