Papers
Topics
Authors
Recent
AI Research Assistant
AI Research Assistant
Well-researched responses based on relevant abstracts and paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses.
Gemini 2.5 Flash
Gemini 2.5 Flash 78 tok/s
Gemini 2.5 Pro 50 tok/s Pro
GPT-5 Medium 15 tok/s Pro
GPT-5 High 15 tok/s Pro
GPT-4o 92 tok/s Pro
Kimi K2 169 tok/s Pro
GPT OSS 120B 469 tok/s Pro
Claude Sonnet 4 37 tok/s Pro
2000 character limit reached

Reflection imaging with a helium zone plate microscope (2308.11749v1)

Published 22 Aug 2023 in physics.ins-det

Abstract: Neutral helium atom microscopy is a novel microscopy technique that offers strictly surface-sensitive, non-destructive imaging. Several experiments have been published in recent years where images are obtained by scanning a helium beam spot across a surface and recording the variation in scattered intensity at a fixed total scattering angle $\theta_{sd}$ and fixed incident angle $\theta_{i}$ relative to the overall surface normal. These experiments used a spot obtained by collimating the beam (referred to as helium pinhole microscopy). Alternatively, a beam spot can be created by focusing the beam with an atom optical element. However up till now imaging with a focused helium beam (referred to as helium zone plate microscopy) has only been demonstrated in transmission. Here we present the first reflection images obtained with a focused helium beam. Images are obtained with a spot size (FWHM) down to 4.7 $\mu$m $\pm$ 0.5 $\mu$m, and we demonstrate focusing down to a spot size of about 1 $\mu$m. Furthermore, we present the first experiments measuring the scattering distribution from a focused helium beam spot. The experiments are done by varying the incoming beam angle $\theta_{i}$ while keeping the beam-detector angle $\theta_{sd}$ and the point where the beam spot hits the surface fixed - in essence, a microscopy scale realization of a standard helium atom scattering experiment. Our experiments are done using an electron bombardment detector with adjustable signal accumulation, developed particularly for helium microscopy.

Citations (3)

Summary

We haven't generated a summary for this paper yet.

Lightbulb On Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.