Explain the TEAM-7 200 Hz measurement discrepancy
Determine the cause of the systematic discrepancy between the converged RAT-EC and finite-element simulations and the published TEAM-7 measurements at 200 Hz, and ascertain whether the simulations fall within the measurement uncertainty.
References
The cause of the discrepancy remains unclear. Since does not state the measurement uncertainty, it cannot be determined whether the simulations lie within it. This would require a new measurement at 200\,Hz, which to our knowledge has not been published.
— RAT-EC: Introducing a New Open-Source 3D Volume-Integral Eddy-Current Module