Cause of residual organ-at-risk dose differences

Identify whether the residual organ-at-risk dose offset between uncertainty-guided digital twin online adaptive proton therapy plans and physician-approved offline replans is attributable to reuse of the offline replan objective template, use of patient-specific robust margins, or another component of the planning framework.

Background

The online adaptive plans achieved target coverage and spinal-cord and brainstem tolerance comparable to the offline replans, but exhibited residual increases in organ-at-risk doses, including spinal cord, brainstem, oral cavity, and parotid doses. The differences were concentrated in a small number of patients and structures near steep dose gradients.

The study reused each patient's offline-replan objective template and applied the patient-specific uncertainty-guided robust margins to the online plans. Because these factors were not varied independently, the authors could not determine which one produced the observed organ-at-risk dose offset. Disentangling their contributions remains an unresolved methodological question for improving the framework.

References

The online plans reused the objective template of the offline replan without further tuning and were optimized with the patient-specific margins of Table 2 as their setup uncertainty; which of these accounts for the OAR offset cannot be separated with the present data, and the offset kept eight of ten online plans within ±2% of the baseline score for either starting point.