Papers
Topics
Authors
Recent
Search
2000 character limit reached

Acquisition state behaves as a structured, measurable variable governing lung-nodule AI: kernel-driven measurement instability and noise-driven detection fragility, invisible to DICOM metadata

Published 11 Jun 2026 in eess.IV, cs.AI, cs.CV, and physics.med-ph | (2606.12824v1)

Abstract: AI governance for medical imaging is formalizing: the 2026 ACR-SIIM Practice Parameter recommends local acceptance testing and ongoing drift monitoring, and the ACR Assess-AI registry monitors AI outputs using DICOM metadata for context. We argue that a necessary, currently unmonitored layer sits beneath output metrics: whether incoming studies remain within the acquisition envelope a model was validated on. Using a LUNA16-trained MONAI RetinaNet lung-nodule detector, we test whether acquisition state behaves as a structured, measurable variable. On real paired CT differing only in reconstruction kernel (NLST B30f vs B80f), kernel alone shifted AI-measured diameter and flipped a Fleischner size category in 5.2% (8 of 155) of nodules at fixed patient and acquisition, while detection confidence was unchanged (Wilcoxon p=0.22). Under controlled LIDC-IDRI perturbations the effects dissociated by axis: the noise axis degraded detection confidence (p=5.9e-32, concentrated in nodules under 6 mm) but not measurement, while the frequency/kernel axis corrupted measurement (p=8.6e-13) but not detection. A 4-feature pixel fingerprint recovered reconstruction identity (patient-level AUC about 0.95 on real CT, 0.995 on a QIBA phantom) where the ConvolutionKernel DICOM tag was uninformative (identical labels across reconstructions). The kernel axis transported across four manufacturers (leave-one-vendor-out AUC 0.94-0.98, matching the within-vendor ceiling). Acquisition state thus maps to distinct AI failure modes, frequency content to measurement reliability and noise to detection sensitivity, and is not recoverable from metadata. Acquisition-aware, input-side validation is the missing layer for the acceptance-testing and drift-monitoring requirements now entering imaging-AI accreditation.

Authors (1)

Summary

No one has generated a summary of this paper yet.

Paper to Video (Beta)

No one has generated a video about this paper yet.

Whiteboard

No one has generated a whiteboard explanation for this paper yet.

Open Problems

We haven't generated a list of open problems mentioned in this paper yet.

Continue Learning

We haven't generated follow-up questions for this paper yet.

Collections

Sign up for free to add this paper to one or more collections.

Tweets

Sign up for free to view the 1 tweet with 0 likes about this paper.