Abstract: Unplanned failures in industrial hydraulic pumps can halt production and incur substantial costs. We explore two unsupervised autoencoder (AE) schemes for early fault detection: a feed-forward model that analyses individual sensor snapshots and a Long Short-Term Memory (LSTM) model that captures short temporal windows. Both networks are trained only on healthy data drawn from a minute-level log of 52 sensor channels; evaluation uses a separate set that contains seven annotated fault intervals. Despite the absence of fault samples during training, the models achieve high reliability.