Papers
Topics
Authors
Recent
Assistant
AI Research Assistant
Well-researched responses based on relevant abstracts and paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses.
Gemini 2.5 Flash
Gemini 2.5 Flash 175 tok/s
Gemini 2.5 Pro 52 tok/s Pro
GPT-5 Medium 36 tok/s Pro
GPT-5 High 38 tok/s Pro
GPT-4o 92 tok/s Pro
Kimi K2 218 tok/s Pro
GPT OSS 120B 442 tok/s Pro
Claude Sonnet 4.5 38 tok/s Pro
2000 character limit reached

Use of solid fused silica etalon with broadband metallic coatings for calibration of high-resolution optical spectrograph (2507.22560v1)

Published 30 Jul 2025 in astro-ph.IM, astro-ph.EP, physics.ins-det, and physics.optics

Abstract: Wavelength calibration is a key factor for high-resolution spectroscopic measurements for precision radial velocities. Hollow-cathode lamps (e.g., ThAr), absorption cells (e.g., iodine cell), dielectric coated Fabry-P\'erot etalons and laser frequency combs have been implemented over the years for precise wavelength calibration and wavelength drift measurements. However, due to their various impediments as wavelength calibrators, investigations of alternative methods remain of prime interest. In this paper, we examined the feasibility of low-cost (~ $1000) commercially available solid fused silica etalon with a broadband metallic coating as a calibrator. We studied the behaviour for two cavity spacings (free spectral range of 1/cm and 0.5/cm) with temperature from theoretical derivation and experimental data. Our setup had a temperature stability of 0.8 mK for a calibrator system using an off-the-shelf dewar flask with active stabilisation. Our result from radial velocity drift measurements demonstrated that such a calibration system is capable of providing higher signal-to-noise calibration and better nightly drift measurement relative to ThAr in the wavelength range between 470 nm and 780 nm. A similar result has been previously found for Fabry-P\'erot etalons, and although the metalon solution lacks the efficiency of an etalon, it does offers a cost-effective broadband solution, which should be less prone to aging relative to complex dielectric mirror coatings. Nonetheless, long-term monitoring is required to understand the metalon behaviour in detail.

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Open Problems

We haven't generated a list of open problems mentioned in this paper yet.

Lightbulb Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.