Synthesizing Late-Stage Contrast Enhancement in Breast MRI: A Comprehensive Pipeline Leveraging Temporal Contrast Enhancement Dynamics
Abstract: Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is essential for breast cancer diagnosis due to its ability to characterize tissue through contrast agent kinetics. However, traditional DCE-MRI protocols require multiple imaging phases, including early and late post-contrast acquisitions, leading to prolonged scan times, patient discomfort, motion artifacts, high costs, and limited accessibility. To overcome these limitations, this study presents a pipeline for synthesizing late-phase DCE-MRI images from early-phase data, replicating the time-intensity (TI) curve behavior in enhanced regions while maintaining visual fidelity across the entire image. The proposed approach introduces a novel loss function, Time Intensity Loss (TI-loss), leveraging the temporal behavior of contrast agents to guide the training of a generative model. Additionally, a new normalization strategy, TI-norm, preserves the contrast enhancement pattern across multiple image sequences at various timestamps, addressing limitations of conventional normalization methods. Two metrics are proposed to evaluate image quality: the Contrast Agent Pattern Score ($\mathcal{CP}_{s}$), which validates enhancement patterns in annotated regions, and the Average Difference in Enhancement ($\mathcal{ED}$), measuring differences between real and generated enhancements. Using a public DCE-MRI dataset with 1.5T and 3T scanners, the proposed method demonstrates accurate synthesis of late-phase images that outperform existing models in replicating the TI curve's behavior in regions of interest while preserving overall image quality. This advancement shows a potential to optimize DCE-MRI protocols by reducing scanning time without compromising diagnostic accuracy, and bringing generative models closer to practical implementation in clinical scenarios to enhance efficiency in breast cancer imaging.
- arXiv:https://doi.org/10.1148/radiol.212530, doi:10.1148/radiol.212530. URL https://doi.org/10.1148/radiol.212530
- doi:10.3389/fonc.2021.661945.
- doi:https://doi.org/10.1016/j.ejro.2020.100307.
- arXiv:https://doi.org/10.1148/radiol.221822, doi:10.1148/radiol.221822. URL https://doi.org/10.1148/radiol.221822
- arXiv:https://doi.org/10.1148/radiol.222211, doi:10.1148/radiol.222211. URL https://doi.org/10.1148/radiol.222211
- doi:10.1109/BHI50953.2021.9508579.
- arXiv:https://aapm.onlinelibrary.wiley.com/doi/pdf/10.1002/mp.15578, doi:https://doi.org/10.1002/mp.15578.
- doi:10.7150/ijms.77906. URL https://www.medsci.org/v20p0163.htm
- doi:https://doi.org/10.1016/j.acra.2014.04.013.
- arXiv:https://onlinelibrary.wiley.com/doi/pdf/10.1002/jmri.26291, doi:https://doi.org/10.1002/jmri.26291. URL https://onlinelibrary.wiley.com/doi/abs/10.1002/jmri.26291
- doi:https://doi.org/10.1016/j.crad.2023.03.006.
- arXiv:https://doi.org/10.1259/bjr.20190302, doi:10.1259/bjr.20190302. URL https://doi.org/10.1259/bjr.20190302
- doi:10.1214/aoms/1177703732. URL https://doi.org/10.1214/aoms/1177703732
- Medixant, Radiant dicom viewer. URL https://www.radiantviewer.com
Paper Prompts
Sign up for free to create and run prompts on this paper using GPT-5.
Top Community Prompts
Collections
Sign up for free to add this paper to one or more collections.