Papers
Topics
Authors
Recent
Assistant
AI Research Assistant
Well-researched responses based on relevant abstracts and paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses.
Gemini 2.5 Flash
Gemini 2.5 Flash 70 tok/s
Gemini 2.5 Pro 48 tok/s Pro
GPT-5 Medium 27 tok/s Pro
GPT-5 High 24 tok/s Pro
GPT-4o 75 tok/s Pro
Kimi K2 175 tok/s Pro
GPT OSS 120B 447 tok/s Pro
Claude Sonnet 4 36 tok/s Pro
2000 character limit reached

Towards 10 cm/s radial velocity accuracy on the Sun using a Fourier transform spectrometer (2311.05520v1)

Published 9 Nov 2023 in astro-ph.IM

Abstract: The IAG solar observatory is producing high-fidelity, ultra-high-resolution spectra (R>500000) of the spatially resolved surface of the Sun using a Fourier Transform spectrometer (FTS). The radial velocity (RV) calibration of these spectra is currently performed using absorption lines from Earth's atmosphere, limiting the precision and accuracy. To improve the frequency calibration precision and accuracy we plan to use a Fabry-Perot etalon (FP) setup that is an evolution of the CARMENES FP design and an iodine cell in combination. To create an accurate wavelength solution, the iodine cell is measured in parallel with the FP. The FP can then be used to transfer the accurate wavelength solution provided by the iodine via simultaneous calibration of solar observations. To verify the stability and precision of the FTS we perform parallel measurements of the FP and an iodine cell. The measurements show an intrinsic stability of the FTS of a level of 1 m/s over 90 hours. The difference between the FP RVs and the iodine cell RVs show no significant trends during the same time span. The RMS of the RV difference between FP and iodine cell is 10.7 cm/s, which can be largely attributed to the intrinsic RV precisions of the iodine cell and the FP (10.2 cm/s and 1.0 cm/s, respectively). This shows that we can calibrate the FTS to a level of 10 cm/s, competitive with current state-of-the-art precision RV instruments. Based on these results we argue that the spectrum of iodine can be used as an absolute reference to reach an RV accuracy of 10 cm/s.

Summary

We haven't generated a summary for this paper yet.

Lightbulb Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Don't miss out on important new AI/ML research

See which papers are being discussed right now on X, Reddit, and more:

“Emergent Mind helps me see which AI papers have caught fire online.”

Philip

Philip

Creator, AI Explained on YouTube