Papers
Topics
Authors
Recent
Gemini 2.5 Flash
Gemini 2.5 Flash 92 tok/s
Gemini 2.5 Pro 50 tok/s Pro
GPT-5 Medium 11 tok/s
GPT-5 High 14 tok/s Pro
GPT-4o 99 tok/s
GPT OSS 120B 462 tok/s Pro
Kimi K2 192 tok/s Pro
2000 character limit reached

Mass Measurement of $^{27}$P to Constrain Type-I X-ray Burst Models and Validate the IMME for the A=27, T=$\frac{3}{2}$ Isospin Quartet (2306.10163v2)

Published 16 Jun 2023 in nucl-ex and astro-ph.HE

Abstract: Light curves are the primary observable of type-I x-ray bursts. Computational x-ray burst models must match simulations to observed light curves. Most of the error in simulated curves comes from uncertainties in $rp$ process reaction rates, which can be reduced via precision mass measurements of neutron-deficient isotopes in the $rp$ process path. We perform a precise Penning trap mass measurement of ${27}$P utilizing the ToF-ICR technique. We use this measurement to calculate $rp$ process reaction rates and input these rates into an x-ray burst model to reduce simulated light curve uncertainty. We also use the mass measurement of ${27}$P to validate the Isobaric Multiplet Mass Equation (IMME) for the A=27 T=$\frac{3}{2}$ isospin quartet which ${27}$P belongs to. The mass excess of ${27}$P was measured to be -670.7(6) keV, a fourteen-fold precision increase over the mass reported in the 2020 Atomic Mass Evaluation (AME2020). X-ray burst light curves were produced with the MESA (Modules for Experiments in Stellar Astrophysics) code using the new mass and associated reaction rates. Changes in the mass of ${27}$P seem to have minimal effect on light curves, even in burster systems tailored to maximize impact. The mass of ${27}$P does not play a significant role in x-ray burst light curves. It is important to understand that more advanced models do not just provide more precise results, but often qualitatively different ones. This result brings us a step closer to extracting stellar parameters from individual x-ray burst observations. The IMME has been validated for the $A=27, T=3/2$ quartet. The normal quadratic form of the IMME using the latest data yields a reduced $\chi2$ of 2.9. The cubic term required to generate an exact fit to the latest data matches theoretical attempts to predict this term.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

We haven't generated a summary for this paper yet.

Ai Generate Text Spark Streamline Icon: https://streamlinehq.com

Paper Prompts

Sign up for free to create and run prompts on this paper using GPT-5.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-up Questions

We haven't generated follow-up questions for this paper yet.