Alpha-decay-correlated mass measurement of 206,207Ra using an $α$-TOF detector equipped MRTOF-MS system
Abstract: The atomic masses of the isotopes ${206,207}$Ra have been measured via decay-correlated mass spectroscopy using a multi-reflection time-of-flight mass spectrograph equipped with an $\alpha$-TOF detector. The Ra isotopes were produced as fusion-evaporation products in the ${51}$V+${159}$Tb reaction system and delivered by the gas-filled recoil ion separator GARIS-II at RIKEN. The $\alpha$-TOF detector provides for high-accuracy mass measurements by correlating time-of-flight signals with subsequent $\alpha$-decay events. The masses of ${206}$Ra and ${207g,m}$Ra were directly measured using a multi-reflection time-of-flight mass spectrograph equipped with an $\alpha$-TOF detector. A mass excess of ME = 3538(15) keV/c$2$ and an excitation energy of E$_{\rm ex}$ = 552(42) keV were determined. The $\alpha$-decay branching ratio of ${207m}$Ra, b$\alpha$ = 0.26(20), was directly determined from decay-correlated time-of-flight signals, and the reduced alpha width of ${207m}$Ra was calculated to be $\delta2$ = 50+62-41 keV from the branching ratio. The spin-parity of ${207m}$Ra was confirmed to be $J\pi$ = 13/2$-$ from decay correlated mass measurement results.