Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 54 tok/s
Gemini 2.5 Pro 50 tok/s Pro
GPT-5 Medium 18 tok/s Pro
GPT-5 High 31 tok/s Pro
GPT-4o 105 tok/s Pro
Kimi K2 182 tok/s Pro
GPT OSS 120B 466 tok/s Pro
Claude Sonnet 4 40 tok/s Pro
2000 character limit reached

Neutron background measurement for rare event search experiments in the YangYang Underground Laboratory (2102.07205v1)

Published 14 Feb 2021 in nucl-ex

Abstract: Several experiments have been conducted in the YangYang Underground Laboratory in the Republic of Korea such as the search for dark matter and the search for neutrinoless double-beta decay, which require an extremely low background event rate due to the detector system and the environment. In underground experiments, neutrons have been identified as one of the background sources. The neutron flux in the experimental site needs to be determined to design a proper shielding system and for precise background estimation. We measured the neutron spectrum with a Bonner sphere spectrometer, with Helium-3 (${3}$He) proportional counters. The neutron flux at the underground laboratory was so low that the radioactive decays from the radioisotopes contained in the detector created a significant background interference to the neutron measurement. Using Monte Carlo simulations, the intrinsic $\alpha$ background distribution due to the radioactive isotopes in the detector materials, was estimated. The neutron count rate of each Bonner sphere was measured from the pulse height spectrum of the ${3}$He proportional counter, after subtracting the $\alpha$ particle background. The neutron flux and the energy spectrum were determined using the unfolding technique. The total neutron flux measured was (4.46 $\pm$ 0.66) $\times$ $10{-5}$ $\rm{cm{-2} s{-1}}$, and the thermal and fast neutron flux (in the range 1 to 10 MeV) were (1.44 $\pm$ 0.15) $\times$ 10${-5}$ $\rm{cm{-2} s{-1}}$ and (0.71 $\pm$ 0.10) $\times$ 10${-5}$ $\rm{cm{-2} s{-1}}$, respectively.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-Up Questions

We haven't generated follow-up questions for this paper yet.