Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 47 tok/s
Gemini 2.5 Pro 37 tok/s Pro
GPT-5 Medium 15 tok/s Pro
GPT-5 High 11 tok/s Pro
GPT-4o 101 tok/s Pro
Kimi K2 195 tok/s Pro
GPT OSS 120B 465 tok/s Pro
Claude Sonnet 4 37 tok/s Pro
2000 character limit reached

First performance evaluation of a Multi-layer Thick Gaseous Electron Multiplier with in-built electrode meshes - MM-THGEM (1804.04643v1)

Published 12 Apr 2018 in physics.ins-det

Abstract: We describe a new micro-pattern gas detector structure comprising a multi-layer hole-type multiplier (M-THGEM) combined with two in-built electrode meshes: the Multi-Mesh THGEM-type multiplier (MM-THGEM). Suitable potential differences applied between the various electrodes provide an efficient collection of ionization electrons within the MM-THGEM holes and a large charge avalanche multiplication between the meshes. Different from conventional hole-type multipliers (e.g. Gas Electron Multipliers - GEMs, Thick Gas Electron Multipliers - THGEMs, etc.), which are characterized by a variable (dipole-like) field strength inside the avalanche gap, electrons in MM-THGEMs are largely multiplied by a strong uniform field established between the two meshes, like in the parallel-plate avalanche geometry. The presence of the two meshes within the holes allows for the trapping of a large fraction of the positive ions that stream back to the drift region. A gas gain above 105 has been achieved for single photo-electron detection with a single MM-THGEM in Ar/(10%)CH4 and He/(10%)CO2, at standard conditions for temperature and pressure. When the MM-THGEM is coupled to a conventional THGEM and used as first cascade element, the maximum achievable gains reach values above 106 in He/(10%)CO2, while the IBF approaches of 1.5% in the case of optimum detector-bias configuration. This IBF value is several times lower compared to the one obtained by a double GEM/THGEM detector (5-10%), and equivalent to the performance attained by a Micromegas detector.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-Up Questions

We haven't generated follow-up questions for this paper yet.