Papers
Topics
Authors
Recent
Gemini 2.5 Flash
Gemini 2.5 Flash
91 tokens/sec
Gemini 2.5 Pro Premium
52 tokens/sec
GPT-5 Medium
24 tokens/sec
GPT-5 High Premium
28 tokens/sec
GPT-4o
85 tokens/sec
DeepSeek R1 via Azure Premium
87 tokens/sec
GPT OSS 120B via Groq Premium
478 tokens/sec
Kimi K2 via Groq Premium
221 tokens/sec
2000 character limit reached

Apodized phase mask coronagraphs for arbitrary apertures (1212.6222v1)

Published 26 Dec 2012 in astro-ph.IM

Abstract: Phase masks coronagraphs can be seen as linear systems that spatially redistribute, in the pupil plane, the energy collected by the telescope. Most of the on-axis light must ideally be rejected outside the aperture to be blocked with a Lyot stop, while almost all off-axis light must go through it. The unobstructed circular apertures of off-axis telescopes make this possible but all major telescopes are however on-axis and the performance of these coronagraphs is dramatically reduced by the central obstruction. Their performance can be restored by using an additional optimally designed apodizer that changes the amplitude in the first pupil plane so that the on-axis light is rejected outside the obstructed aperture of the telescope. The numerical optimization model is built by maximizing the apodizer's transmission while setting constraints on the extremum values of the electric field that the Lyot stop does not block. The coronagraphic image is compared to what a non-apodized phase mask coronagraph provides and an analysis is made of the trade-offs that exist between the apodizer transmission and the Lyot stop properties. The existence of a solution and the mask transmission depend on the aperture and the Lyot stop geometries, and on the constraints that are set on the on-axis attenuation. The system throughput is a concave function of the Lyot stop transmission. In the case of a VLT-like aperture, apodizers with a transmission of 0.16 to 0.92 associated with a four-quadrant phase mask provide contrast as low as a few 1e-10 at 1 lambda/D from the star. The system's maximum throughput is 0.64, for an apodizer with an 0.88 transmission and a Lyot stop with a 0.69 transmission. Optimizing apodizers for a vortex phase mask requires computation times much longer than in the previous case, and no result is presented for this mask.

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-up Questions

We haven't generated follow-up questions for this paper yet.

Authors (1)

Don't miss out on important new AI/ML research

See which papers are being discussed right now on X, Reddit, and more:

“Emergent Mind helps me see which AI papers have caught fire online.”

Philip

Philip

Creator, AI Explained on YouTube