Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 45 tok/s
Gemini 2.5 Pro 52 tok/s Pro
GPT-5 Medium 30 tok/s Pro
GPT-5 High 24 tok/s Pro
GPT-4o 96 tok/s Pro
Kimi K2 206 tok/s Pro
GPT OSS 120B 457 tok/s Pro
Claude Sonnet 4 36 tok/s Pro
2000 character limit reached

Probing low-mass WIMP candidates of dark matter with tetrafluoroethane superheated liquid detectors (1905.04706v2)

Published 12 May 2019 in hep-ph and astro-ph.GA

Abstract: Probing low mass (sub-GeV -- few GeV) Weakly Interacting Massive Particle (WIMP) candidates of dark matter through WIMP-induced nuclear recoils in direct detection experiments requires use of detector materials consisting of low mass target nuclei and low threshold energy. Here we explore the potential of superheated liquid detectors (SLD) with a hydrogen containing liquid, namely, tetrafluoroethane (C${2}$H${2}$F${4}$) (b.p.~$-26.3\circ\,$C), as the target material for probing low mass WIMPs. It is found that few-keV level recoil energy thresholds possible for bubble nucleation by WIMP-induced ${12}$C and ${19}$F recoils in C${2}$H${2}$F${4}$ SLDs operated at atmospheric pressure and gamma-ray insensitive temperatures of $T\, \lesssim\, 35\circ\,$C have the potential to allow WIMPs in the few-GeV mass range to be probed at a WIMP-nucleon spin-independent cross section sensitivity levels (90% C.L.) better than $4.6\times 10{-5}\,$pb at WIMP masses down to $\sim$ 4 GeV with a total exposure of $\sim$ 1000 kg.day, provided that the ``thermodynamic efficiency" $\eta_{\rm T}$ that determines the bubble nucleation thresholds for the recoiling nuclei in C${2}$H${2}$F${4}$ is $\sim$ 50% or higher. Sensitivity to sub-GeV WIMP masses generally requires the detector to be sensitive to the WIMP-induced $1$H recoils, which in turn requires the detector to be operated at temperatures $T\gtrsim 50\circ\,$C and $\eta{\rm T}$ close to 100%. At such relatively high temperatures (at atmospheric pressure), however, the detector would be sensitive to background gamma rays.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-Up Questions

We haven't generated follow-up questions for this paper yet.