Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 45 tok/s
Gemini 2.5 Pro 52 tok/s Pro
GPT-5 Medium 30 tok/s Pro
GPT-5 High 24 tok/s Pro
GPT-4o 96 tok/s Pro
Kimi K2 206 tok/s Pro
GPT OSS 120B 457 tok/s Pro
Claude Sonnet 4 36 tok/s Pro
2000 character limit reached

A Comprehensive Simulation Study of a Liquid-Xe Detector for Contraband Detection (1501.00150v1)

Published 31 Dec 2014 in physics.ins-det

Abstract: Recently, a new detector concept, for combined imaging and spectroscopy of fast-neutrons and gamma was presented. It encompasses a liquid-xenon (LXe) converter-scintillator coupled to a UV-sensitive gaseous Thick Gas Electron Multiplier (THGEM)-based imaging photomultiplier (GPM). In this work we present and discuss the results of a systematic computer-simulation study aiming at optimizing the type and performance of LXe converter. We have evaluated the detector spectral response, detection efficiency and spatial resolution for gamma-rays and neutrons in the energy range of 2-15 MeV for 50 mm thick converters consisting of plain LXe volume and LXe-filled capillaries, of Teflon, Polyethylene or hydrogen-containing Teflon (Tefzel). Neutron detection efficiencies for plain LXe, Teflon-capillaries and Tefzel-capillaries converters were about 20% over the entire energy range. In polyethylene capillaries converters the neutron detection efficiency was about 10% at 2 MeV and increased up to about 20% at 14 MeV. Detection efficiencies of gammas in Teflon, Tefzel and polyethylene converters were ~35%. The plain-LXe converter provided the highest gamma-ray detection efficiency, of ~40-50% for 2-15 MeV energy range. Optimization of LXe-filled Tefzel capillary dimensions resulted in spatial resolution of ~1.5mm (FWHM) for neutrons and up to 3.5 mm (FWHM) for gamma-rays. Simulations of radiographic images of various materials using two discrete energy gamma-rays (4.4 MeV and 15.1 MeV) and neutrons in broad energy range (2-10 MeV) were performed in order to evaluate the potential of elemental discrimination.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-Up Questions

We haven't generated follow-up questions for this paper yet.