Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 71 tok/s
Gemini 2.5 Pro 52 tok/s Pro
GPT-5 Medium 18 tok/s Pro
GPT-5 High 15 tok/s Pro
GPT-4o 101 tok/s Pro
Kimi K2 196 tok/s Pro
GPT OSS 120B 467 tok/s Pro
Claude Sonnet 4 37 tok/s Pro
2000 character limit reached

The nature of filamentary cold gas in the core of the Virgo Cluster (1211.6722v2)

Published 28 Nov 2012 in astro-ph.CO

Abstract: We present a multi-wavelength study of the emission-line nebulae located southeast of the nucleus of M87, the central dominant galaxy of the Virgo Cluster. We report the detection of far-infrared (FIR) [CII] line emission from the nebulae using observations made with Herschel PACS. The infrared line emission is extended and cospatial with optical H{\alpha}+[NII], far-ultraviolet CIV lines, and soft X-ray emission. The filamentary nebulae evidently contain multi-phase material spanning a temperature range of at least 5 orders of magnitude, from ~100 K to ~107 K. This material has most likely been uplifted by the AGN from the center of M87. The thermal pressure of the 104 K phase appears to be significantly lower than that of the surrounding hot intra-cluster medium (ICM) indicating the presence of additional turbulent and magnetic pressure in the filaments. If the turbulence in the filaments is subsonic then the magnetic field strength required to balance the pressure of the surrounding ICM is B~30-70 {\mu}G. The spectral properties of the soft X-ray emission from the filaments indicate that it is due to thermal plasma with kT~0.5-1 keV, which is cooling by mixing with the cold gas and/or radiatively. Charge exchange can be ruled out as a significant source of soft X-rays. Both cooling and mixing scenarios predict gas with a range of temperatures. This is at first glance inconsistent with the apparent lack of X-ray emitting gas with kT<0.5 keV. However, we show that the missing very soft X-ray emission could be absorbed by the cold gas in the filaments with an integrated hydrogen column density of ~1.6x1021 cm-2, providing a natural explanation for the apparent temperature floor to the X-ray emission at kT~0.5 keV. The FIR through ultra-violet line emission is most likely primarily powered by the ICM particles penetrating the cold gas following a shearing induced mixing process.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-Up Questions

We haven't generated follow-up questions for this paper yet.