Papers
Topics
Authors
Recent
Assistant
AI Research Assistant
Well-researched responses based on relevant abstracts and paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses.
Gemini 2.5 Flash
Gemini 2.5 Flash 173 tok/s
Gemini 2.5 Pro 47 tok/s Pro
GPT-5 Medium 43 tok/s Pro
GPT-5 High 44 tok/s Pro
GPT-4o 94 tok/s Pro
Kimi K2 180 tok/s Pro
GPT OSS 120B 438 tok/s Pro
Claude Sonnet 4.5 36 tok/s Pro
2000 character limit reached

Detection of retinal diseases using an accelerated reused convolutional network (2510.04232v1)

Published 5 Oct 2025 in cs.CV and cs.LG

Abstract: Convolutional neural networks are continually evolving, with some efforts aimed at improving accuracy, others at increasing speed, and some at enhancing accessibility. Improving accessibility broadens the application of neural networks across a wider range of tasks, including the detection of eye diseases. Early diagnosis of eye diseases and consulting an ophthalmologist can prevent many vision disorders. Given the importance of this issue, various datasets have been collected from the cornea to facilitate the process of making neural network models. However, most of the methods introduced in the past are computationally complex. In this study, we tried to increase the accessibility of deep neural network models. We did this at the most fundamental level, specifically by redesigning and optimizing the convolutional layers. By doing so, we created a new general model that incorporates our novel convolutional layer named ArConv layers. Thanks to the efficient performance of this new layer, the model has suitable complexity for use in mobile phones and can perform the task of diagnosing the presence of disease with high accuracy. The final model we present contains only 1.3 million parameters. In comparison to the MobileNetV2 model, which has 2.2 million parameters, our model demonstrated better accuracy when trained and evaluated on the RfMiD dataset under identical conditions, achieving an accuracy of 0.9328 versus 0.9266 on the RfMiD test set.

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Open Problems

We haven't generated a list of open problems mentioned in this paper yet.

Lightbulb Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.