STEPC: A Pixel-wise Nonuniformity Correction Framework for Photon-Counting CT in Multi-material Imaging Scenarios (2507.14963v1)

Published 20 Jul 2025 in physics.med-ph

Abstract: Photon-counting computed tomography (PCCT) has demonstrated significant advancements in recent years; however, pixel-wise detector response nonuniformity remains a key challenge, frequently manifesting as ring artifacts in reconstructed images. Existing correction methods exhibit limited generalizability in complex multi-material scenarios, such as contrast-enhanced imaging. This study introduces a Signal-to-Uniformity Error Polynomial Calibration (STEPC) framework to address this issue. STEPC first fits multi-energy projections using a 2D polynomial surface to generate ideal references, then applies a nonlinear multi-energy polynomial model to predict and correct pixel-wise nonuniformity errors. The model is calibrated using homogeneous slab phantoms of different materials, including PMMA, aluminum, and iodinated contrast agents, enabling correction for both non-contrast and contrast-enhanced imaging. Experiments were performed on a custom Micro-PCCT system with phantoms and mouse. Correction performance of STEPC was evaluated using the mean local standard deviation (MLSD) in the projection domain and the ring artifact deviation (RAD) on the reconstructed images. STEPC consistently outperformed existing correction methods in both non-contrast and contrast-enhanced scenarios. It achieved the lowest MLSD and RAD for both phantoms and mouse scans. These results indicate that STEPC provides a robust and practical solution for correcting detector nonuniformity in multi-material PCCT imaging, witch position it as a promising general-purpose calibration framework for photon-counting CT systems.

Summary

We haven't generated a summary for this paper yet.

Lightbulb Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.