High-accuracy multi-ion spectroscopy with mixed-species Coulomb crystals (2501.09615v1)
Abstract: Multi-ion optical clocks offer the possibility of overcoming the low signal-to-noise ratio of single-ion clocks, while still providing low systematic uncertainties. We present simultaneous spectroscopy of up to four ${}{115}$In${}+$ clock ions in a linear Coulomb crystal, sympathetically cooled with ${}{172}$Yb${}+$ ions. In first clock comparisons, we see agreement below $1\times10{-17}$ with results obtained using a single In${}+$ ion, for which we have evaluated the systematic uncertainty to be $2.5\times10{-18}$. Operation with four clock ions reduces the instability from $1.6\times10{-15}/\sqrt{t/(1\;\mathrm{s})}$ to $9.2\times10{-16}/\sqrt{t/(1\;\mathrm{s})}$. We derive a model for decay-related dead time during state preparation, which matches the observed scaling of instability with clock ion number $N$, and indicates that $1/\sqrt{N}$ scaling can be achieved with the addition of a repump laser.