Papers
Topics
Authors
Recent
Assistant
AI Research Assistant
Well-researched responses based on relevant abstracts and paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses.
Gemini 2.5 Flash
Gemini 2.5 Flash 71 tok/s
Gemini 2.5 Pro 54 tok/s Pro
GPT-5 Medium 22 tok/s Pro
GPT-5 High 29 tok/s Pro
GPT-4o 88 tok/s Pro
Kimi K2 138 tok/s Pro
GPT OSS 120B 446 tok/s Pro
Claude Sonnet 4.5 35 tok/s Pro
2000 character limit reached

Bi-Band ECoGNet for ECoG Decoding on Classification Task (2412.00378v3)

Published 30 Nov 2024 in math.NA, cs.CV, and cs.NA

Abstract: In the application of brain-computer interface (BCI), being able to accurately decode brain signals is a critical task. For the multi-class classification task of brain signal ECoG, how to improve the classification accuracy is one of the current research hotspots. ECoG acquisition uses a high-density electrode array and a high sampling frequency, which makes ECoG data have a certain high similarity and data redundancy in the temporal domain, and also unique spatial pattern in spatial domain. How to effectively extract features is both exciting and challenging. Previous work found that visual-related ECoG can carry visual information via frequency and spatial domain. Based on this finding, we focused on using deep learning to design frequency and spatial feature extraction modules, and proposed a Bi-Band ECoGNet model based on deep learning. The main contributions of this paper are: 1) The Bi-BCWT (Bi-Band Channel-Wise Transform) neural network module is designed to replace the time-consume method MST, this module greatly improves the model calculation and data storage efficiency, and effectively increases the training speed; 2) The Bi-BCWT module can effectively take into account the information both in low-frequency and high-frequency domain, which is more conducive to ECoG multi-classification tasks; 3) ECoG is acquired using 2D electrode array, the newly designed 2D Spatial-Temporal feature encoder can extract the 2D spatial feature better. Experiments have shown that the unique 2D spatial data structure can effectively improve classification accuracy; 3) Compared with previous work, the Bi-Band ECoGNet model is smaller and has higher performance, with an accuracy increase of 1.24%, and the model training speed is increased by 6 times, which is more suitable for BCI applications.

Citations (1)

Summary

We haven't generated a summary for this paper yet.

Lightbulb Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

Authors (1)

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Don't miss out on important new AI/ML research

See which papers are being discussed right now on X, Reddit, and more:

“Emergent Mind helps me see which AI papers have caught fire online.”

Philip

Philip

Creator, AI Explained on YouTube