Beam test of a baseline vertex detector prototype for CEPC (2404.03688v1)

Published 2 Apr 2024 in physics.ins-det and hep-ex

Abstract: The Circular Electron Positron Collider (CEPC) has been proposed to enable more thorough and precise measurements of the properties of Higgs, W, and Z bosons, as well as to search for new physics. In response to the stringent performance requirements of the vertex detector for the CEPC, a baseline vertex detector prototype was tested and characterized for the first time using a 6 GeV electron beam at DESY II Test Beam Line 21. The baseline vertex detector prototype is designed with a cylindrical barrel structure that contains six double-sided detector modules (ladders). Each side of the ladder includes TaichuPix-3 sensors based on Monolithic Active Pixel Sensor (MAPS) technology, a flexible printed circuit, and a carbon fiber support structure. Additionally, the readout electronics and the Data Acquisition system were also examined during this beam test. The performance of the prototype was evaluated using an electron beam that passed through six ladders in a perpendicular direction. The offline data analysis indicates a spatial resolution of about 5 um, with detection efficiency exceeding 99 % and an impact parameter resolution of about 5.1 um. These promising results from this baseline vertex detector prototype mark a significant step toward realizing the optimal vertex detector for the CEPC.

Definition Search Book Streamline Icon: https://streamlinehq.com
References (16)
  1. The CEPC Study Group, “CEPC Conceptual Design Report: Volume 2 - Physics & Detector,” 11 2018.
  2. R. Diener, J. Dreyling-Eschweiler, H. Ehrlichmann, I. Gregor, U. Kötz, U. Krämer, N. Meyners, N. Potylitsina-Kube, A. Schütz, P. Schütze, and M. Stanitzki, “The DESY II test beam facility,” Nucl. Instrum. Meth. A, vol. 922, pp. 265–286, 2019.
  3. L. Chen, Y. Zhang, H. Zhu, X. Ai, M. Fu, R. Kiuchi, Y. Liu, Z. Liu, X. Lou, Y. Lu, Q. Ouyang, X. Shi, J. Tao, K. Wang, N. Wang, C. Yang, and Y. Zhou, “Characterization of the prototype cmos pixel sensor jadepix-1 for the cepc vertex detector,” JINST, vol. 14, no. 05, p. C05023, may 2019.
  4. Y. Zhou, Y. Lu, Z. Wu, T. Shi, X. Ju, J. Dong, H. Zhu, and Q. Ouyang, “Highly compact digital pixel structures developed for the cepc vertex detector,” Nucl. Instrum. Methods A, vol. 980, p. 164427, 2020.
  5. T. Wu et al., “The TaichuPix1: a monolithic active pixel sensor with fast in-pixel readout electronics for the CEPC vertex detector,” JINST, vol. 16, no. 09, p. P09020, 2021.
  6. Y. Zhang et al., “Development of a CMOS pixel sensor prototype for the high hit rate CEPC vertex detector,” Nucl. Instrum. Meth. A, vol. 1042, p. 167442, 2022.
  7. G. Aglieri Rinella, “The alpide pixel sensor chip for the upgrade of the alice inner tracking system,” Nucl. Instrum. Methods A, vol. 845, pp. 583–587, 2017, proceedings of the Vienna Conference on Instrumentation 2016.
  8. B. Abelev et al., “Technical Design Report for the Upgrade of the ALICE Inner Tracking System,” Tech. Rep., 2014.
  9. I. Perić, L. Blanquart, G. Comes, P. Denes, K. Einsweiler, P. Fischer, E. Mandelli, and G. Meddeler, “The fei3 readout chip for the atlas pixel detector,” Nucl. Instrum. Methods A, vol. 565, no. 1, pp. 178–187, 2006, proceedings of the International Workshop on Semiconductor Pixel Detectors for Particles and Imaging.
  10. X. Wei et al., “High data-rate readout logic design of a 512 × 1024 pixel array dedicated for CEPC vertex detector,” JINST, vol. 14, no. 12, p. C12012, 2019.
  11. T. Wu, S. Li, W. Wang et al., “Beam test of a 180nm cmos pixel sensor for the cepc vertex detector,” Nucl. Instrum. Methods A, vol. 1059, p. 168945, 2024.
  12. W. Snoeys et al., “A process modification for CMOS monolithic active pixel sensors for enhanced depletion, timing performance and radiation tolerance,” Nucl. Instrum. Meth. A, vol. 871, pp. 90–96, 2017.
  13. J. Fu et al., “Mechanical design of an ultra-light vertex detector prototype for cepc,” Radiat. Detect. Technol. Methods, vol. 6, pp. 159 – 169, 2022.
  14. C. Kleinwort, “General broken lines as advanced track fitting method,” Nucl. Instrum. Methods A, vol. 673, pp. 107–110, 2012.
  15. V. Blobel, “Software alignment for tracking detectors,” Nucl. Instrum. Methods A, vol. 566, no. 1, pp. 5–13, 2006, tIME 2005.
  16. V. L. Highland, “Some practical remarks on multiple scattering,” Nucl. Instrum. Methods, vol. 129, no. 2, pp. 497–499, 1975.
Citations (1)

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Open Problems

We haven't generated a list of open problems mentioned in this paper yet.

Lightbulb Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

X Twitter Logo Streamline Icon: https://streamlinehq.com

Tweets

This paper has been mentioned in 1 tweet and received 0 likes.

Upgrade to Pro to view all of the tweets about this paper: