Papers
Topics
Authors
Recent
Assistant
AI Research Assistant
Well-researched responses based on relevant abstracts and paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses.
Gemini 2.5 Flash
Gemini 2.5 Flash 71 tok/s
Gemini 2.5 Pro 54 tok/s Pro
GPT-5 Medium 22 tok/s Pro
GPT-5 High 29 tok/s Pro
GPT-4o 88 tok/s Pro
Kimi K2 138 tok/s Pro
GPT OSS 120B 446 tok/s Pro
Claude Sonnet 4.5 35 tok/s Pro
2000 character limit reached

Focal-plane wavefront sensing with the vector Apodizing Phase Plate (1909.08317v1)

Published 18 Sep 2019 in astro-ph.IM

Abstract: In this article we show that the vector-Apodizing Phase Plate (vAPP) coronagraph can be designed such that the coronagraphic point spread functions (PSFs) can act as a wavefront sensor to measure and correct the (quasi-)static aberrations, without dedicated wavefront sensing holograms nor modulation by the deformable mirror. The absolute wavefront retrieval is performed with a non-linear algorithm. The focal-plane wavefront sensing (FPWFS) performance of the vAPP and the algorithm are evaluated with numerical simulations, to test various photon and read noise levels, the sensitivity to the 100 lowest Zernike modes and the maximum wavefront error (WFE) that can be accurately estimated in one iteration. We apply these methods to the vAPP within SCExAO, first with the internal source and subsequently on-sky. In idealised simulations we show that for $107$ photons the root-mean-square (RMS) WFE can be reduced to $\sim\lambda/1000$, which is 1 nm RMS in the context of the SCExAO system. We find that the maximum WFE that can be corrected in one iteration is $\sim\lambda/8$ RMS or $\sim$200 nm RMS (SCExAO). Furthermore, we demonstrate the SCExAO vAPP capabilities by measuring and controlling the lowest 30 Zernike modes with the internal source and on-sky. On-sky, we report a raw contrast improvement of a factor $\sim$2 between 2 and 4 $\lambda/D$ after 5 iterations of closed-loop correction. When artificially introducing 150 nm RMS WFE, the algorithm corrects it within 5 iterations of closed-loop operation. FPWFS with the vAPP's coronagraphic PSFs is a powerful technique since it integrates coronagraphy and wavefront sensing, eliminating the need for additional probes and thus resulting in a $100\%$ science duty cycle and maximum throughput for the target.

Citations (19)

Summary

We haven't generated a summary for this paper yet.

Lightbulb Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Don't miss out on important new AI/ML research

See which papers are being discussed right now on X, Reddit, and more:

“Emergent Mind helps me see which AI papers have caught fire online.”

Philip

Philip

Creator, AI Explained on YouTube