Papers
Topics
Authors
Recent
Assistant
AI Research Assistant
Well-researched responses based on relevant abstracts and paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses.
Gemini 2.5 Flash
Gemini 2.5 Flash 71 tok/s
Gemini 2.5 Pro 54 tok/s Pro
GPT-5 Medium 22 tok/s Pro
GPT-5 High 29 tok/s Pro
GPT-4o 88 tok/s Pro
Kimi K2 138 tok/s Pro
GPT OSS 120B 446 tok/s Pro
Claude Sonnet 4.5 35 tok/s Pro
2000 character limit reached

Enhancing the Resolution Limits of Spectral Interferometric Measurements with Swept-Wavelength Interrogation by Means of a Reference Interferometer (1904.12656v1)

Published 25 Apr 2019 in physics.ins-det and physics.optics

Abstract: An approach for compensating the influence of the interrogator noises on the readings of interferometric sensors, interrogated by means of spectral interferometry with wavelength tuning is proposed. Both theoretical analysis and a proof-of-principle experiment were performed for the example of extrinsic Fabry-Perot interferometers (EFPI). Two schemes, comprising of a signal and a reference interferometers, switched in different optical channels of the interrogating unit, were proposed. The approach is based on the fact that the fluctuations of some of the interrogator parameters produce correlated fluctuations of the reference and signal interferometers optical path differences (OPD) measured values. The fluctuations of the reference interferometers measured OPD can be subtracted from the measured OPD of the signal interferometer. The fluctuations of different parameters of the interrogator are considered, the correlation properties of the produced noises of the measured OPD values are demonstrated. The first scheme contains two interferometers with similar parameters and enabled a three-fold resolution improvement in the performed experiments, when the difference of the interferometers OPDs was varied within about 10 nm. The second scheme contains two interferometers with OPDs difference such that all interrogator fluctuations, except for the dominating one produce uncorrelated OPD errors. With the second scheme a two-fold resolution improvement was experimentally demonstrated, when the interferometers OPDs difference was varied within more than 1 \mum. The proposed approach can be used for improving the resolution of interferometric sensors with relatively large OPDs (greater than 200-300 \mum), which can be advantageous for remote materials and surface inspection.

Summary

We haven't generated a summary for this paper yet.

Lightbulb Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.