Sharpness-aware Low dose CT denoising using conditional generative adversarial network (1708.06453v2)

Published 22 Aug 2017 in cs.CV

Abstract: Low Dose Computed Tomography (LDCT) has offered tremendous benefits in radiation restricted applications, but the quantum noise as resulted by the insufficient number of photons could potentially harm the diagnostic performance. Current image-based denoising methods tend to produce a blur effect on the final reconstructed results especially in high noise levels. In this paper, a deep learning based approach was proposed to mitigate this problem. An adversarially trained network and a sharpness detection network were trained to guide the training process. Experiments on both simulated and real dataset shows that the results of the proposed method have very small resolution loss and achieves better performance relative to the-state-of-art methods both quantitatively and visually.

Citations (241)

Summary

  • The paper introduces a novel SAGAN architecture that integrates a sharpness detection network to enhance denoising while preserving fine image details.
  • It employs a Unet256-based generator and a patch-based discriminator, achieving superior PSNR and SSIM compared to traditional methods.
  • Experimental evaluations on simulated and clinical datasets validate SAGAN’s effectiveness in reducing noise and maintaining diagnostic quality.

Sharpness-Aware Low Dose CT Denoising Using Conditional Generative Adversarial Network

This paper investigates the application of deep learning techniques to address the challenges of noise reduction in low-dose computed tomography (LDCT) imaging. The proposed solution leverages the capabilities of Conditional Generative Adversarial Networks (cGANs), introducing a novel Sharpness-Aware Generative Adversarial Network (SAGAN) to achieve superior image denoising while maintaining the high resolution and sharpness critical for effective medical diagnostics.

Core Contributions

The research identifies the limitations of traditional noise reduction methods that often lead to blurring, especially in high-noise conditions, thus compromising diagnostic usability. The authors propose the use of an adversarial framework wherein a generator network and a discriminator network are trained in opposition to achieve more accurate noise reduction. Additionally, the SAGAN architecture integrates a separate sharpness detection network that assesses the sharpness of resulting images, emphasizing the restoration of low-contrast details - a feature critical for medical imaging where subtle gradients might indicate pathological conditions.

Generator Design: A Unet256 architecture with residual components is utilized, which reportedly stabilizes training processes and enhances detail recovery. The architecture efficiently balances the preservation of fine-grained details with the robustness necessary to manage high noise variance.

Discriminator Modifications: The discriminator is designed to evaluate patches of the images rather than whole images, increasing the adaptability of the system to various image sizes and potentially improving generalization across different anatomical regions and scanning protocols.

Sharpness Loss Integration: Inspired by the inadequacy of pixel-wise error minimization strategies, a sharpness-aware mechanism is incorporated to guide the generator in recovering edge and fine structure information. This approach aligns with strategies used in perceptual loss contexts but targets sharpness directly, assisted by pretrained networks that learn to identify visual clarity markers in image data.

Quantitative Evaluation

The paper employs a range of experimental settings to test the SAGAN framework's efficacy against other established methods, such as BM3D and K-SVD, across both simulated and real datasets. Numerical results demonstrated in this research reveal that the SAGAN model outperforms these traditional methods in terms of both PSNR and SSIM across varied noise levels. The PSNR and SSIM measurements underscore SAGAN's ability to deliver high-quality image restoration while retaining crucial spatial resolution.

Simulated and Real Data Testing: With simulations generated through varying levels of photon counts to mimic real-world scanning conditions, along with real piglet and clinical datasets, the paper demonstrates the versatility and robustness of the model. Particularly remarkable is the system's performance in handling ultra-low-dose scenarios without substantial loss of diagnostic quality, as evidenced by the spatial resolution tests performed on the Catphan 600 high-resolution CT phantom.

Noise Reduction Impact: The measure of standard deviation of CT numbers across smooth regions further quantifies SAGAN's ability to maintain image fidelity. The noise reduction factor achieved situates SAGAN as a promising candidate for practical deployment in clinical imaging environments where dose minimization is paramount.

Implications and Future Directions

The methodologies outlined in this paper not only contribute significantly to the field of medical imaging but also open the door for further innovations in task-specific adaptive networks. The demonstrated capacity to maintain clarity and resolution in LDCT imagery suggests potential applicability to other medical imaging areas requiring low signal-to-noise ratio contexts, such as MRI or ultrasound.

Looking forward, there is scope to refine the sharpness orchestration by extending the training datasets and refining the sharpness detection network to identify subtler blurring effects. The generalizability of this approach across unseen dose levels and different types of imaging apparatus highlights both the adaptability and the potential necessity for integrating such systems into existing medical imaging workflows to enhance patient care standards.

Overall, the paper effectively addresses a critical challenge in radiology, offering a sophisticated solution grounded in contemporary AI methodologies. Such advancements promise to facilitate breakthroughs in dose management, particularly pivotal in radiological health sciences where minimizing patient exposure is constantly weighed against the need for diagnostic precision.

Dice Question Streamline Icon: https://streamlinehq.com

Open Questions

We haven't generated a list of open questions mentioned in this paper yet.