Published 28 Jun 2013 in gr-qc and physics.optics

Abstract: KAGRA is a cryogenic interferometric gravitational wave detector being constructed at the underground site of Kamioka mine in Gifu prefecture, Japan. We performed an optimization of the interferomter design, to achieve the best sensitivity and a stable operation, with boundary conditions of classical noises and under various practical constraints, such as the size of the tunnel or the mirror cooling capacity. Length and alignment sensing schemes for the robust control of the interferometer are developed. In this paper, we describe the detailed design of the KAGRA interferometer as well as the reasoning behind design choices.

Citations (626)

Summary

  • The paper introduces KAGRA’s cryogenic interferometer design that reduces thermal noise by using mono-crystalline sapphire mirrors cooled to about 20K.
  • It details innovative seismic isolation and dual sideband RF modulation for precise length sensing and robust control under tunnel size constraints.
  • The study applies quantum non-demolition techniques and optical spring effects to optimize detector sensitivity in both broad-band and detuned RSE configurations.

Interferometer Design of the KAGRA Gravitational Wave Detector

The paper under review presents a comprehensive design framework for the KAGRA gravitational wave detector, a cryogenically operated interferometer situated in the subterranean confines of the Kamioka mine in Japan. The design is oriented towards optimizing the detector's sensitivity, considering several constraints such as thermal noise from cryogenic mirrors, seismic noise mitigation, and a stringent tunnel size limitation.

Design Challenges and Solutions

KAGRA's innovative features include the use of mono-crystalline sapphire mirrors, cooled down to approximately 20 Kelvin, to reduce the thermal noise and thus improve detection sensitivity. This design choice mandates an efficient heat extraction mechanism, which is elegantly handled through the use of high thermal conductivity suspension wires and differentiated cryocooler connections. The seismic isolation is achieved by utilizing a two-story seismic attenuation system, leveraging the naturally quiet environment of the Kamioka mine.

Optimization of Interferometer Sensitivity

The optimization process primarily focuses on mitigating quantum noises while keeping classical noises as boundary conditions. The quantum non-demolition techniques adopted in KAGRA, such as the back-action evasion and optical spring effect, align with optimizing parameters like the arm cavity finesse and signal recycling mirror reflectivity. The paper reports on a seemingly paradoxical requirement to achieve variable detuning—operating the detector in both broad-band RSE (BRSE) and detuned RSE (DRSE) configurations. The decision here is driven by the trade-off between improving inspiral range for initial detection versus rich scientific data extraction from specific gravitational wave events.

Length Sensing and Control Schema

The authors explore the complexity of length sensing and control strategies, an integral component for maintaining optimal operation points of the mirror system. They propose a dual sideband RF modulation scheme to differentiate the various length degrees of freedom effectively. The intricacy of this design is highlighted by the careful choice of RF sideband frequencies and macroscopic lengths of the power and signal recycling cavities to minimize loop noise coupling while ensuring robust signal extraction from the interferometer.

Spatial Mode Control and Mirror Design

Notable attention is given to spatial mode control within KAGRA, where the interplay between mirror curvature radii and Gouy phase shifts is meticulously explored. The g-factor analysis for the arm cavities is insightful, offering a nuanced approach to balancing beam spot size to thermal noise. Implementing a folded design for the recycling cavities compensates for potential spatial mode degeneracy, with an alignment toward minimizing higher-order mode excitations. This design choice is pertinent, given the implications on mode mismatch losses and thermal lensing impact, as discussed in the paper.

Implications and Future Directions

From a theoretical perspective, the authors argue convincingly for the design’s potential to enhance gravitational wave detection capabilities and provide empirical validation for its underlying principles. Practically, the implementation of this design could serve as a benchmark for the next generation of interferometers, setting a precedent in cryogenic optical techniques. However, the alignment control shot noise remains a critical challenge, hinting at the necessity for ongoing refinements in both suspension control systems and alignment sensing technologies.

In summary, the KAGRA interferometer design embodies a sophisticated confluence of innovative cryogenics, seismic isolation, and quantum optics. It is well-positioned to advance our understanding of gravitational waves, subject to overcoming the described instrumental challenges. Looking ahead, the paper suggests potential further developments in AI-assisted interferometer control, thermally-resilient materials, and quantum measurement techniques, which may redefine expected sensitivities in future endeavors.