Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 84 tok/s
Gemini 2.5 Pro 45 tok/s Pro
GPT-5 Medium 28 tok/s Pro
GPT-5 High 21 tok/s Pro
GPT-4o 92 tok/s Pro
GPT OSS 120B 425 tok/s Pro
Kimi K2 157 tok/s Pro
2000 character limit reached

An Empirical Calibration of the Tip of the Red Giant Branch Distance Method in the Near Infrared. II. JWST NIRCam Wide Filters (2406.03532v2)

Published 5 Jun 2024 in astro-ph.CO

Abstract: The tip of the red giant (TRGB) is a standardizable candle and is identifiable as the discontinuity at the bright extreme of the red giant branch (RGB) stars in color-magnitude diagram (CMD) space. The TRGB-based distance method has been calibrated and used to measured distances to galaxies out to $D\leq20$ Mpc with the $I$-band equivalent Hubble Space Telescope ($HST$) $F814W$ filter, and as an important rung in the distance ladder to measure the Hubble constant, $H_0$. In the infrared (IR), the TRGB apparent magnitude ranges from $1-2$ magnitudes brighter than in the optical, and now with the IR James Webb Space Telescope ($JWST$) observatory the feasible distance range of the TRGB method can be extended to $\sim50$ Mpc. However, in the IR the TRGB luminosity depends to varying degrees on stellar metallicity and age. In this study we standardize the TRGB luminosity using stellar colors as a proxy for metallicity/age to derive color-based corrections for the $JWST$ Near-Infrared Camera (NIRCam) short wavelength (SW) filters $F090W$, $F115W$, $F150W$ and the long wavelength (LW) filters $F277W$, $F356W,$ and $F444W$. We provide recommended filter combinations for distance measurements depending on the requisite precision. For science requiring high precision ($\leq1\%$ in distance) and robustness we recommend measuring the TRGB in $F090W$ vs $F090W-F150W$ or $F115W$ vs. $F115W-F277W$ with the caveat that even with $JWST$ long integration times will be necessary at further distances. If lower precision ($>1.5\%$ in distance) can be tolerated, or if shorter integration times are desirable, we recommend measuring the TRGB in either $F115W$ or $F150W$ paired with $F356W$. We do not recommend $F444W$ for precision TRGB measurements due to its lower angular resolution.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

We haven't generated a summary for this paper yet.

Ai Generate Text Spark Streamline Icon: https://streamlinehq.com

Paper Prompts

Sign up for free to create and run prompts on this paper using GPT-5.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-up Questions

We haven't generated follow-up questions for this paper yet.