Slice energy spread measurement in the low energy photoinjector
Abstract: Slice energy spread is one of the key parameters in free electron laser optimizations, but its accurate measurement is not straightforward. Two recent studies from high energy ($>$100 MeV) photoinjectors at SwissFEL and European XFEL have reported much higher slice energy spread than expected at their XFEL working points (200 - 250 pC). In this paper, a new method for measuring slice energy spread at a lower beam energy ($\sim$20 MeV) is proposed and demonstrated at the PhotoInjector Test facility at DESY Zeuthen (PITZ), and the results for 250 pC and 500 pC are much lower than those measured at high energy injectors.
Paper Prompts
Sign up for free to create and run prompts on this paper using GPT-5.
Top Community Prompts
Collections
Sign up for free to add this paper to one or more collections.