Papers
Topics
Authors
Recent
Assistant
AI Research Assistant
Well-researched responses based on relevant abstracts and paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses.
Gemini 2.5 Flash
Gemini 2.5 Flash 175 tok/s
Gemini 2.5 Pro 52 tok/s Pro
GPT-5 Medium 36 tok/s Pro
GPT-5 High 38 tok/s Pro
GPT-4o 92 tok/s Pro
Kimi K2 218 tok/s Pro
GPT OSS 120B 442 tok/s Pro
Claude Sonnet 4.5 38 tok/s Pro
2000 character limit reached

Develop of a Pneumatic Force Sensor Prototype (2201.00290v1)

Published 2 Jan 2022 in cs.RO

Abstract: One of the difficulties of applying a SEA force control is the complexity that exists when implementing its three main components, which must work together one after the other. To facilitate the implementation of a force control by SEA, in this thesis the pneumatic force sensor is developed. A pneumatic force sensor differs from other force sensors in that it can work as a force sensor and as an elastic element. These features facilitate the implementation of force control by SEA, by reducing the number of components required. On the other hand, the pneumatic force sensor has reduced proportions to facilitate its installation in manipulator robots and biomechatronic prostheses. The first step that was made for the development of the pneumatic force sensor was the construction of the mathematical model of the sensor, to later use the MATLAB / Simulink software to simulate it. With the data obtained from the simulation of the mathematical model, the CAD model and the sensor planes were developed in SolidWorks software. Subsequently, the prototype of the pneumatic force sensor was built based on the plans made in the SolidWorks software. Once the stage of construction of the pneumatic force sensor was completed, the calibration and classification of the force sensor was carried out based on the UNE-EN ISO 376 standard, and the experimental tests were carried out to validate the sensor. Once the classification of the pneumatic force sensor was obtained, the results of the simulation of the mathematical model were compared with the results of the experimental test. vi In the comparison, it was possible to show a graphic coherence in the results obtained, validating the pneumatic force sensor system.

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Open Problems

We haven't generated a list of open problems mentioned in this paper yet.

Lightbulb Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.