Papers
Topics
Authors
Recent
Assistant
AI Research Assistant
Well-researched responses based on relevant abstracts and paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses.
Gemini 2.5 Flash
Gemini 2.5 Flash 80 tok/s
Gemini 2.5 Pro 60 tok/s Pro
GPT-5 Medium 23 tok/s Pro
GPT-5 High 26 tok/s Pro
GPT-4o 87 tok/s Pro
Kimi K2 173 tok/s Pro
GPT OSS 120B 433 tok/s Pro
Claude Sonnet 4 36 tok/s Pro
2000 character limit reached

Improving Heart Rate Estimation on Consumer Grade Wrist-Worn Device Using Post-Calibration Approach (1910.07881v5)

Published 14 Oct 2019 in eess.SP

Abstract: The technological advancement in wireless health monitoring through the direct contact of the skin allows the development of light-weight wrist-worn wearable devices to be equipped with different sensors such as photoplethysmography (PPG) sensors. However, the motion artifact (MA) is possible to occur during daily activities. In this study, we attempted to perform a post-calibration of the heart rate (HR) estimation during the three possible states of average daily activity (resting, \textcolor{red}{laying down}, and intense treadmill activity states) in 29 participants (130 minutes/person) on four popular wearable devices: Fitbit Charge HR, Apple Watch Series 4, TicWatch Pro, and Empatica E4. In comparison to the standard measurement (HR$\text{ECG}$), HR provided by Fitbit Charge HR (HR$\text{Fitbit}$) yielded the highest error of $3.26 \pm 0.34$ bpm in resting, $2.33 \pm 0.23$ bpm in \textcolor{red}{laying down}, $9.53 \pm 1.47$ bpm in intense treadmill activity states, and $5.02 \pm 0.64$ bpm in all states combined among the four chosen devices. Following our improving HR estimation model with rolling windows as feature (HR$_\text{R}$), the mean absolute error (MAE) was significantly reduced by $33.44\%$ in resting, $15.88\%$ in \textcolor{red}{laying down}, $9.55\%$ in intense treadmill activity states, and $18.73\%$ in all states combined. This demonstrates the feasibility of our proposed methods in order to correct and provide HR monitoring post-calibrated with high accuracy, raising further awareness of individual fitness in the daily application.

Summary

We haven't generated a summary for this paper yet.

Lightbulb Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.