Papers
Topics
Authors
Recent
Assistant
AI Research Assistant
Well-researched responses based on relevant abstracts and paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses.
Gemini 2.5 Flash
Gemini 2.5 Flash 77 tok/s
Gemini 2.5 Pro 56 tok/s Pro
GPT-5 Medium 33 tok/s Pro
GPT-5 High 21 tok/s Pro
GPT-4o 107 tok/s Pro
Kimi K2 196 tok/s Pro
GPT OSS 120B 436 tok/s Pro
Claude Sonnet 4.5 34 tok/s Pro
2000 character limit reached

Priority Choice Experimental Two-qubit Tomography: Measuring One by One All Elements of Density Matrices (1506.01317v1)

Published 3 Jun 2015 in quant-ph

Abstract: In standard optical tomographic methods, the off-diagonal elements of a density matrix $\rho$ are measured indirectly. Thus, the reconstruction of $\rho$, even if it is based on linear inversion, typically magnifies small errors in the experimental data. Recently, an optimal tomography [Phys. Rev. A 90, 062123 (2014)] has been proposed theoretically to measure one-by-one all the elements of $\rho$. Thus, the relative errors in the reconstructed state can be the same as those in the experimental data. We implemented this method for two-qubit polarization states performing both local and global measurements. For comparison, we also experimentally implemented other well-known tomographic protocols based solely on local measurements (of, e.g., the Pauli operators and James-Kwiat-Munro-White projectors) and those with mutually unbiased bases requiring both local and global measurements. We reconstructed seventeen of two-qubit polarization states including separable, partially and maximally entangled. Our experiments show the highest stability against errors of our method in comparison to the other quantum tomographies. In particular, we demonstrate that each optimally-reconstructed state} is embedded in the uncertainty circle of the smallest radius, both in terms of the trace distance and disturbance. We explain how to estimate experimentally the uncertainty radii for all the implemented tomographies and show that, for each reconstructed state, the relevant uncertainty circles intersect indicating the approximate location of the corresponding physical density matrix.

Summary

We haven't generated a summary for this paper yet.

Lightbulb Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.