Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 77 tok/s
Gemini 2.5 Pro 33 tok/s Pro
GPT-5 Medium 25 tok/s Pro
GPT-5 High 27 tok/s Pro
GPT-4o 75 tok/s Pro
Kimi K2 220 tok/s Pro
GPT OSS 120B 465 tok/s Pro
Claude Sonnet 4 36 tok/s Pro
2000 character limit reached

A GPU-accelerated computational fluid dynamics solver for assessing shear-driven indoor airflow and virus transmission by scale-resolved simulations (2204.02107v1)

Published 5 Apr 2022 in physics.flu-dyn

Abstract: We explore the applicability of MATLAB for 3D computational fluid dynamics (CFD) of shear-driven indoor airflows. A new scale-resolving, large-eddy simulation (LES) solver titled DNSLABIB is proposed for MATLAB utilizing graphics processing units (GPUs). The solver is first validated against another CFD software (OpenFOAM). Next, we demonstrate the solver performance in three isothermal indoor ventilation configurations and the results are discussed in the context of airborne transmission of COVID-19. Ventilation in these cases is studied at both low (0.1 m/s) and high (1 m/s) airflow rates corresponding to $Re=5000$ and $Re=50000$. An analysis of the indoor CO$_2$ concentration is carried out as the room is emptied from stale, high CO$_2$ content air. We estimate the air changes per hour (ACH) values for three different room geometries and show that the numerical estimates from 3D CFD simulations may differ by 80-150 % ($Re=50000$) and 75-140 % ($Re=5000$) from the theoretical ACH value based on the perfect mixing assumption. Additionally, the analysis of the CO$_2$ probability distributions (PDFs) indicates a relatively non-uniform distribution of fresh air indoors. Finally, utilizing a time-dependent Wells-Riley analysis, an example is provided on the growth of the cumulative infection risk being reduced rapidly after the ventilation is started. The average infection risk is shown to reduce by a factor of 2 for lower ventilation rates (ACH=3.4-6.3) and 10 for the higher ventilation rates (ACH=37-64). The results indicate a high potential for DNSLABIB in various future developments on airflow prediction.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-Up Questions

We haven't generated follow-up questions for this paper yet.