Papers
Topics
Authors
Recent
AI Research Assistant
AI Research Assistant
Well-researched responses based on relevant abstracts and paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses.
Gemini 2.5 Flash
Gemini 2.5 Flash 77 tok/s
Gemini 2.5 Pro 52 tok/s Pro
GPT-5 Medium 30 tok/s Pro
GPT-5 High 31 tok/s Pro
GPT-4o 91 tok/s Pro
Kimi K2 178 tok/s Pro
GPT OSS 120B 385 tok/s Pro
Claude Sonnet 4 38 tok/s Pro
2000 character limit reached

Skin marker-based subject-specific spinal alignment modeling: A feasibility study (2101.12272v2)

Published 28 Jan 2021 in physics.med-ph, physics.bio-ph, and q-bio.QM

Abstract: Musculoskeletal models have the potential to improve diagnosis and optimize clinical treatment by predicting accurate outcomes on an individual basis. However, the subject-specific modeling of spinal alignment is often strongly simplified or is based on radiographic assessments, exposing subjects to unnecessary radiation. We therefore developed a novel skin marker-based approach for modeling subject-specific spinal alignment and evaluated its feasibility by comparing the predicted with the actual intervertebral joint (IVJ) locations/orientations (ground truth) using lateral-view radiographic images. Moreover, the predictive performance of the subject-specific models was evaluated by comparing the predicted L1/L2 spinal loads during various functional activities with in vivo measured data obtained from the OrthoLoad database. IVJ locations/orientations were predicted closer to ground truth as opposed to standard model scaling, with average location prediction errors of 0.99+/-0.68 cm on the frontal and 1.21+/-0.97 cm on the transverse axis as well as an average orientation prediction error of 4.74{\deg}+/-2.80{\deg}. Simulated spinal loads showed similar curve patterns but considerably larger values as compared to in vivo measured data. Differences in spinal loads between generic and subject-specific models become only apparent on an individual subject level. These results underline the feasibility of the proposed method and associated workflow for inter- and intra-subject investigations using musculoskeletal simulations. When implemented into standard model scaling workflows, it is expected to improve the accuracy of muscle activity and joint loading simulations, which is crucial for investigations of treatment effects or pathology-dependent deviations.

Summary

We haven't generated a summary for this paper yet.

Lightbulb On Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Don't miss out on important new AI/ML research

See which papers are being discussed right now on X, Reddit, and more:

“Emergent Mind helps me see which AI papers have caught fire online.”

Philip

Philip

Creator, AI Explained on YouTube