Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 71 tok/s
Gemini 2.5 Pro 52 tok/s Pro
GPT-5 Medium 18 tok/s Pro
GPT-5 High 15 tok/s Pro
GPT-4o 101 tok/s Pro
Kimi K2 196 tok/s Pro
GPT OSS 120B 467 tok/s Pro
Claude Sonnet 4 37 tok/s Pro
2000 character limit reached

The abundance and physical properties of O VII and O VIII X-ray absorption systems in the EAGLE simulations (1904.01057v2)

Published 1 Apr 2019 in astro-ph.GA and astro-ph.CO

Abstract: We use the EAGLE cosmological, hydrodynamical simulations to predict the column density and equivalent width distributions of intergalactic O VII ($E=574$ eV) and O VIII ($E=654$ eV) absorbers at low redshift. These two ions are predicted to account for 40% of the gas-phase oxygen, which implies that they are key tracers of cosmic metals. We find that their column density distributions evolve little at observable column densities from redshift 1 to 0, and that they are sensitive to AGN feedback, which strongly reduces the number of strong (column density $N \gtrsim 10{16} \, \mathrm{cm}{-2})$ absorbers. The distributions have a break at $N \sim 10{16} \, \mathrm{cm}{-2}$, corresponding to overdensities of $\sim 10{2}$, likely caused by the transition from sheet/filament to halo gas. Absorption systems with $N \gtrsim 10{16} \mathrm{cm}{-2}$ are dominated by collisionally ionized O VII and O VIII, while the ionization state of oxygen at lower column densities is also influenced by photoionization. At these high column densities, O VII and O VIII arising in the same structures probe systematically different gas temperatures, meaning their line ratio does not translate into a simple estimate of temperature. While O VII and O VIII column densities and covering fractions correlate poorly with the H I column density at $N_{\mathrm{H \, I}} \gtrsim 10{15} \, \mathrm{cm}{-2}$, O VII and O VIII column densities are higher in this regime than at the more common, lower H I column densities. The column densities of O VI and especially Ne VIII, which have strong absorption lines in the UV, are good predictors of the strengths of O VII and O VIII absorption and can hence aid in the detection of the X-ray lines.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-Up Questions

We haven't generated follow-up questions for this paper yet.