Choice of tip, signal stability and practical aspects of Piezoresponse-Force-Microscopy (1601.03612v1)

Published 14 Jan 2016 in physics.ins-det and cond-mat.mtrl-sci

Abstract: Piezoresponse force-microscopy (PFM) has become the standard tool to investigate ferroelectrics on the micro- and nanoscale. However, reliability of PFM signals is often problematic and their quantification is challenging and thus not widely applied. Here, we present a study of the reproducibility of PFM signals and of the so-called PFM background signal which has been reported in literature. We find that PFM signals are generally reproducible to certain extents. The PFM signal difference between 180{\deg} domains on periodically-poled lithium niobate (PPLN) is taken as the reference signal in a large number of measurements, carried out in a low frequency regime (30-70 kHz). We show that in comparison to Pt coated tips, diamond coated tips exhibit improved signal stability, lower background signal and less imaging artifacts related to PFM which is reflected in the spread of measurements. This is attributed to the improved mechanical stability of the conductive layer. The average deviation of the mean PFM signal is 38.3%, for a diamond coated tip. Although this deviation is relatively high, it is far better than values from literature which showed a deviation of approx. 73.1%. Additionally, we find that the average deviation of the background signal from 0 is 11.6% of the PPLN domain contrast. Thus, the background signal needs to be taken into account when quantifying PFM signals and should be subtracted from PFM signals. Those results are important for quantification of PFM signals, since PPLN might be used for this purpose when PFM signals measured on PPLN are related to its macroscopic d33 coefficient. Finally, the crucial influence of sample polishing on PFM signals is shown and we recommend to use a multistep polishing route with a final step involving 200 nm sized colloidal silica particles.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

We haven't generated a summary for this paper yet.

Ai Generate Text Spark Streamline Icon: https://streamlinehq.com

Paper Prompts

Sign up for free to create and run prompts on this paper using GPT-5.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-up Questions

We haven't generated follow-up questions for this paper yet.