Trigger and Aperture of the Surface Detector Array of the Pierre Auger Observatory (1111.6764v1)

Published 29 Nov 2011 in astro-ph.IM

Abstract: The surface detector array of the Pierre Auger Observatory consists of 1600 water-Cherenkov detectors, for the study of extensive air showers (EAS) generated by ultra-high-energy cosmic rays. We describe the trigger hierarchy, from the identification of candidate showers at the level of a single detector, amongst a large background (mainly random single cosmic ray muons), up to the selection of real events and the rejection of random coincidences. Such trigger makes the surface detector array fully efficient for the detection of EAS with energy above $3\times 10{18}$ eV, for all zenith angles between 0$\circ$ and 60$\circ$, independently of the position of the impact point and of the mass of the primary particle. In these range of energies and angles, the exposure of the surface array can be determined purely on the basis of the geometrical acceptance.

Citations (201)
List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

Trigger and Aperture of the Surface Detector Array of the Pierre Auger Observatory

The paper, "Trigger and Aperture of the Surface Detector Array of the Pierre Auger Observatory," presents a comprehensive analysis of the trigger and aperture mechanisms of the Surface Detector (SD) component of the Pierre Auger Observatory. This observatory is a significant apparatus devoted to the paper of ultra-high-energy cosmic rays (UHECRs) via extensive air showers (EAS).

The surface detector array, a pivotal part of the observatory, consists of 1600 water-Cherenkov detectors laid out over a vast area in Argentina. This array is essential to capture the lateral distribution of secondary particles resulting from EAS produced by cosmic rays entering the Earth's atmosphere. The architecture of the SD array, combined with a fluorescence detector (FD), provides a dual detection method that enhances the observatory's capability to analyze cosmic ray characteristics such as energy, arrival direction, and mass composition.

Trigger System and Hierarchical Structure

The authors delineate a hierarchical trigger system, developed to manage data acquisition effectively while minimizing irrelevant noise, mainly from single cosmic ray muons. This system ensures the SD array is fully efficient for detecting cosmic ray showers with energies exceeding 3×10183 \times 10^{18} eV, for a range of zenith angles from 0° to 60°. The trigger mechanism is layered to refine event selection and minimize chance coincidences:

  1. Single Detector Triggers (T1 and T2): These local triggers operate independently at each detector to reduce background noise. The T1 triggers operate in two modes: Threshold and Time-over-Threshold (ToT), targeting distinct shower components. The T2 trigger further curtails event rates using a higher threshold for the TH mode, hence managing bandwidth.
  2. Array Trigger (T3): At this stage, the captured T2 trigger data across the detectors are synchronized in time and space to identify valid shower events. The T3 triggers enable data acquisition only when a reliable correlation across detectors is detected.
  3. Offline Event Selection (T4 and T5): This phase involves refinements to ensure only genuine shower events are analyzed. It distinguishes between real events and random noise through geometric pattern recognition and ensures data coverage adequacy via fiducial triggering, which considers only events well-contained within the array.

Efficiency and Exposure

The thoroughness of the trigger system results in a near-zero rate of spurious non-physical events, allowing reliable cosmic ray detection within the targeted energy and angular range. The SD array achieves full efficiency above 3×10183 \times 10^{18} eV, confirmed through both data analysis and simulation methods.

The exposure calculation, essential for flux measurements, is based on the robust determination of the geometrical aperture and the uptime of the array. The combination of precise aperture calculation and detailed monitoring of the active array during data acquisition ensures a minimal uncertainty of under 3% in the integrated exposure estimate.

Practical and Theoretical Implications

The paper underscores the importance of a meticulously designed hierarchical trigger system in large-scale cosmic ray observatories. The approach ensures high data integrity, allowing for extensive research on cosmic ray origins, propagation, and interactions. With full efficiency at high energies, the Pierre Auger Observatory's SD array provides crucial data for the cosmic ray energy spectrum analysis. The methodologies described facilitate not only the current data collection but also future enhancements and technologies in particle astrophysics research.

This framework establishes a paradigm for other observatories, aiming to achieve similar efficiencies in detecting and analyzing high-energy cosmic phenomena. As technological advancements and theoretical models evolve, the observatory's data and operational insights will continue to contribute significantly to the field of astroparticle physics.