Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 89 tok/s
Gemini 2.5 Pro 49 tok/s Pro
GPT-5 Medium 29 tok/s Pro
GPT-5 High 31 tok/s Pro
GPT-4o 98 tok/s Pro
GPT OSS 120B 424 tok/s Pro
Kimi K2 164 tok/s Pro
2000 character limit reached

The Impact of Fiber Cross Contamination on Radial Velocity Precision (2505.19994v1)

Published 26 May 2025 in astro-ph.IM and astro-ph.EP

Abstract: High-resolution spectrographs with precise radial velocity (PRV) capabilities require careful considerations in instrumental design and data processing in order to reach the 10 cm/s-level precision, which is needed for detecting Earth-like planets. In this work, we investigate the impact of fiber cross contamination on the RV precision via simulations, as modern PRV spectrographs often have multiple fiber traces on their spectral images. We simulated extracted 1-D spectra under the preliminary design of CHORUS, short for the Canary Hybrid Optical high-Resolution Ultra-stable Spectrograph, a dual-arm PRV spectrograph under construction for the Gran Telescopio de Canarias. We considered two types of fiber cross contaminations: contamination from calibration traces to neighboring science traces (or cal-sci contamination) and between science traces (or sci-sci contamination). We present results in four different scenarios: photon noise only, cal-sci contamination only, sci-sci contamination only, and all effects combined. For the preliminary design of CHORUS, we estimated that the cal-sci contamination fraction is smaller than 0.0001% in flux across the whole CCD for either arm, resulting in a negligible impact on the RV precision. Assuming worst-case scenarios, we estimated the sci-sci contamination to be up to 0.1% in some traces, corresponding to an additional RV error of up to 10 cm/s. We demonstrate the importance of considering fiber-trace spacing and cross contamination in PRV spectrographs, and we recommend careful design, operation, and spectral extraction algorithms to minimize and mitigate cross contamination to achieve the best possible instrumental RV precision.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

We haven't generated a summary for this paper yet.

Ai Generate Text Spark Streamline Icon: https://streamlinehq.com

Paper Prompts

Sign up for free to create and run prompts on this paper using GPT-5.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-up Questions

We haven't generated follow-up questions for this paper yet.