Papers
Topics
Authors
Recent
Gemini 2.5 Flash
Gemini 2.5 Flash
119 tokens/sec
GPT-4o
56 tokens/sec
Gemini 2.5 Pro Pro
43 tokens/sec
o3 Pro
6 tokens/sec
GPT-4.1 Pro
47 tokens/sec
DeepSeek R1 via Azure Pro
28 tokens/sec
2000 character limit reached

DeepBeat: A multi-task deep learning approach to assess signal quality and arrhythmia detection in wearable devices (2001.00155v2)

Published 1 Jan 2020 in eess.SP, cs.LG, and stat.ML

Abstract: Wearable devices enable theoretically continuous, longitudinal monitoring of physiological measurements like step count, energy expenditure, and heart rate. Although the classification of abnormal cardiac rhythms such as atrial fibrillation from wearable devices has great potential, commercial algorithms remain proprietary and tend to focus on heart rate variability derived from green spectrum LED sensors placed on the wrist where noise remains an unsolved problem. Here, we develop a multi-task deep learning method to assess signal quality and arrhythmia event detection in wearable photoplethysmography devices for real-time detection of atrial fibrillation (AF). We train our algorithm on over one million simulated unlabeled physiological signals and fine-tune on a curated dataset of over 500K labeled signals from over 100 individuals from 3 different wearable devices. We demonstrate that in comparison with a traditional random forest-based approach (precision:0.24, recall:0.58, f1:0.34, auPRC:0.44) and a single task CNN (precision:0.59, recall:0.69, f1:0.64, auPRC:0.68) our architecture using unsupervised transfer learning through convolutional denoising autoencoders dramatically improves the performance of AF detection in participants at rest (pr:0.94, rc:0.98, f1:0.96, auPRC:0.96). In addition, we validate algorithm performance on a prospectively derived replication cohort of ambulatory subjects using data derived from an independently engineered device. We show that two-stage training can help address the unbalanced data problem common to biomedical applications where large well-annotated datasets are scarce. In conclusion, though a combination of simulation and transfer learning and we develop and apply a multitask architecture to the problem of AF detection from wearable wrist sensors demonstrating high levels of accuracy and a solution for the vexing challenge of mechanical noise.

User Edit Pencil Streamline Icon: https://streamlinehq.com
Authors (2)
  1. Jessica Torres Soto (1 paper)
  2. Euan Ashley (4 papers)
Citations (6)

Summary

We haven't generated a summary for this paper yet.