TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical Exercise (1409.5181v3)

Published 18 Sep 2014 in cs.CY

Abstract: Heart rate monitoring using wrist-type photoplethysmographic (PPG) signals during subjects' intensive exercise is a difficult problem, since the signals are contaminated by extremely strong motion artifacts caused by subjects' hand movements. So far few works have studied this problem. In this work, a general framework, termed TROIKA, is proposed, which consists of signal decomposiTion for denoising, sparse signal RecOnstructIon for high-resolution spectrum estimation, and spectral peaK trAcking with verification. The TROIKA framework has high estimation accuracy and is robust to strong motion artifacts. Many variants can be straightforwardly derived from this framework. Experimental results on datasets recorded from 12 subjects during fast running at the peak speed of 15 km/hour showed that the average absolute error of heart rate estimation was 2.34 beat per minute (BPM), and the Pearson correlation between the estimates and the ground-truth of heart rate was 0.992. This framework is of great values to wearable devices such as smart-watches which use PPG signals to monitor heart rate for fitness.

Citations (637)

Summary

  • The paper introduces TROIKA, a comprehensive framework that integrates signal decomposition, sparse signal reconstruction, and spectral peak tracking for robust heart rate estimation during exercise.
  • The methodology employs SSA with acceleration data and the FOCUSS algorithm to achieve high-resolution spectrum estimation in the presence of noise.
  • Experimental evaluations demonstrate an average absolute error of 2.34 BPM and a Pearson correlation of 0.992, outperforming traditional methods in high-intensity scenarios.

Essay on TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical Exercise

The paper presents TROIKA, a novel framework for heart rate (HR) monitoring leveraging wrist-type photoplethysmographic (PPG) signals during intensive physical exercise. This paper addresses significant challenges associated with motion artifacts (MA) contamination, proposing a comprehensive solution comprising three pivotal components: signal decomposition for denoising, sparse signal reconstruction (SSR) for high-resolution spectrum estimation, and spectral peak tracking with rigorously designed verification mechanisms.

Framework Overview

TROIKA distinguishes itself through its systematic approach towards mitigating the formidable issue of motion artifacts during high-intensity activities. Signal decomposition aims to reduce artifacts, primarily by leveraging Singular Spectrum Analysis (SSA), which partitions the signal into components to isolate and discard noise-related segments. This process is critically supported by concurrently recorded acceleration data, ensuring robust motion artifact removal.

SSR, particularly effective in scenarios where traditional spectrum estimations fail due to high noise levels, forms a core component. By employing the FOCUSS algorithm, TROIKA achieves superior spectrum resolution and robustness, crucial attributes for accurate HR estimation. The first-order and second-order temporal differences further enhance spectral sparsity, emphasizing the spectral peaks associated with HR while suppressing MA-induced fluctuations.

Spectral peak tracking completes the framework, utilizing a combination of harmonic analysis and consecutive time window verification to maintain accurate HR tracking amidst erratic MA signals. Strategies to address peak verification ensure consistent performance, even in challenging environments.

Experimental Evaluation

Empirical validations involved datasets from 12 subjects engaged in varying intensities of treadmill activities, revealing the framework’s proficient HR estimation capabilities. The average absolute error of 2.34 BPM and a Pearson correlation of 0.992 substantiate TROIKA’s accuracy and reliability. Performance comparisons with alternative methodologies further underscore its superiority, particularly in scenarios characterized by intensive exercise where previous techniques exhibited significant limitations.

Implications and Future Directions

TROIKA holds substantial implications for modern wearable technology, particularly in fitness and health monitoring domains. Its adaptability to different signal decomposition and SSR methods presents opportunities for customization in various hardware contexts. As wearable devices continue to gain prominence, frameworks such as TROIKA that enhance reliability and user experience will become increasingly critical.

Future research could explore optimization of TROIKA for lower sampling rates, potentially augmenting computational efficiency without compromising accuracy. Additionally, investigating alternative signal decomposition techniques and adapting TROIKA to broader physiological monitoring applications might yield further valuable insights.

Overall, the paper contributes a significant advancement in the integration of mechanical and algorithmic strategies for wearable health monitoring, paving the way for more refined and user-friendly devices.