Cuff-less Arterial Blood Pressure Waveform Synthesis from Single-site PPG using Transformer & Frequency-domain Learning (2401.05452v2)
Abstract: We develop and evaluate two novel purpose-built deep learning (DL) models for synthesis of the arterial blood pressure (ABP) waveform in a cuff-less manner, using a single-site photoplethysmography (PPG) signal. We train and evaluate our DL models on the data of 209 subjects from the public UCI dataset on cuff-less blood pressure (CLBP) estimation. Our transformer model consists of an encoder-decoder pair that incorporates positional encoding, multi-head attention, layer normalization, and dropout techniques for ABP waveform synthesis. Secondly, under our frequency-domain (FD) learning approach, we first obtain the discrete cosine transform (DCT) coefficients of the PPG and ABP signals, and then learn a linear/non-linear (L/NL) regression between them. The transformer model (FD L/NL model) synthesizes the ABP waveform with a mean absolute error (MAE) of 3.01 (4.23). Further, the synthesis of ABP waveform also allows us to estimate the systolic blood pressure (SBP) and diastolic blood pressure (DBP) values. To this end, the transformer model reports an MAE of 3.77 mmHg and 2.69 mmHg, for SBP and DBP, respectively. On the other hand, the FD L/NL method reports an MAE of 4.37 mmHg and 3.91 mmHg, for SBP and DBP, respectively. Both methods fulfill the AAMI criterion. As for the BHS criterion, our transformer model (FD L/NL regression model) achieves grade A (grade B).
- World Health Organization, “First who report details devastating impact of hypertension and ways to stop it.” https://www.who.int/news/item/19-09-2023-first-who-report-details-devastating-impact-of-hypertension-and-ways-to-stop-it, 2023. Accessed on: Jan. 2, 2024.
- P. Nugroho, H. Andrew, K. Kohar, C. A. Noor, and A. L. Sutranto, “Comparison between the world health organization (who) and international society of hypertension (ish) guidelines for hypertension,” Annals of Medicine, vol. 54, no. 1, pp. 837–845, 2022.
- B. Zhou, P. Perel, G. A. Mensah, and M. Ezzati, “Global epidemiology, health burden and effective interventions for elevated blood pressure and hypertension,” Nature Reviews Cardiology, vol. 18, no. 11, pp. 785–802, 2021.
- N. I. Saedon, M. Pin Tan, and J. Frith, “The prevalence of orthostatic hypotension: a systematic review and meta-analysis,” The Journals of Gerontology: Series A, vol. 75, no. 1, pp. 117–122, 2020.
- K. L. Tucker, J. P. Sheppard, R. Stevens, H. B. Bosworth, A. Bove, E. P. Bray, K. Earle, J. George, M. Godwin, B. B. Green, et al., “Self-monitoring of blood pressure in hypertension: a systematic review and individual patient data meta-analysis,” PLoS medicine, vol. 14, no. 9, p. e1002389, 2017.
- B. Saugel, K. Kouz, A. S. Meidert, L. Schulte-Uentrop, and S. Romagnoli, “How to measure blood pressure using an arterial catheter: a systematic 5-step approach,” Critical Care, vol. 24, pp. 1–10, 2020.
- J. A. Pandit, E. Lores, and D. Batlle, “Cuffless blood pressure monitoring: promises and challenges,” Clinical Journal of the American Society of Nephrology: CJASN, vol. 15, no. 10, p. 1531, 2020.
- M. Kachuee, M. M. Kiani, H. Mohammadzade, and M. Shabany, “Cuffless blood pressure estimation algorithms for continuous health-care monitoring,” IEEE Transactions on Biomedical Engineering, vol. 64, no. 4, pp. 859–869, 2016.
- P. M. Nabeel, J. Jayaraj, K. Srinivasa, S. Mohanasankar, and M. Chenniappan, “Bi-modal arterial compliance probe for calibration-free cuffless blood pressure estimation,” IEEE Transactions on Biomedical Engineering, vol. 65, no. 11, pp. 2392–2404, 2018.
- P. Shaltis, A. Reisner, and H. Asada, “A hydrostatic pressure approach to cuffless blood pressure monitoring,” in The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, vol. 1, pp. 2173–2176, 2004.
- J. A. Pandit, E. Lores, and D. Batlle, “Cuffless blood pressure monitoring,” Clinical Journal of the American Society of Nephrology, vol. 15, no. 10, p. 1531–1538, 2020.
- J. Solà and R. Delgado-Gonzalo, “The handbook of cuffless blood pressure monitoring,” Cham: Springer, 2019.
- L.-Y. Shyu, Y.-L. Kao, W.-Y. Tsai, and W. Hu, “Development of a cuffless blood pressure measurement system,” in 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 2040–2043, 2012.
- H. Y. Lee, D.-J. Lee, J. Seo, S.-H. Ihm, K.-i. Kim, E. J. Cho, H. C. Kim, J. Shin, S. Park, I.-S. Sohn, and et al., “Smartphone / smartwatch-based cuffless blood pressure measurement : A position paper from the korean society of hypertension,” Clinical Hypertension, vol. 27, no. 1, 2021.
- J. Baek, J. Kim, N. Kim, D. Lee, and S.-M. Park, “Validation of cuffless blood pressure monitoring using wearable device,” in TENCON 2018 - 2018 IEEE Region 10 Conference, pp. 0416–0419, 2018.
- M. Park, H. Kang, Y. Huh, and K.-C. Kim, “Cuffless and noninvasive measurement of systolic blood pressure, diastolic blood pressure, mean arterial pressure and pulse pressure using radial artery tonometry pressure sensor with concept of korean traditional medicine,” in 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 3597–3600, 2007.
- A. Mehmood, A. Sarouji, M. M. U. Rahman, and T. Y. Al-Naffouri, “Your smartphone could act as a pulse-oximeter and as a single-lead ecg,” Scientific Reports, vol. 13, no. 1, p. 19277, 2023.
- N. Ibtehaz, S. Mahmud, M. E. Chowdhury, A. Khandakar, M. Salman Khan, M. A. Ayari, A. M. Tahir, and M. S. Rahman, “Ppg2abp: Translating photoplethysmogram (ppg) signals to arterial blood pressure (abp) waveforms,” Bioengineering, vol. 9, no. 11, p. 692, 2022.
- R. Mukkamala, J.-O. Hahn, O. T. Inan, L. K. Mestha, C.-S. Kim, H. Töreyin, and S. Kyal, “Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice,” IEEE Transactions on Biomedical Engineering, vol. 62, no. 8, pp. 1879–1901, 2015.
- R. Shriram, A. Wakankar, N. Daimiwal, and D. Ramdasi, “Continuous cuffless blood pressure monitoring based on ptt,” in 2010 International Conference on Bioinformatics and Biomedical Technology, pp. 51–55, IEEE, 2010.
- K. Shimura, M. Hori, T. Dohi, and H. Takao, “The calibration method for blood pressure pulse wave measurement based on arterial tonometry method,” in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp. 1–4, 2018.
- “Ieee standard for wearable cuffless blood pressure measuring devices,” IEEE P1708/D04, June 2014, pp. 1–32, 2014.
- Electronic or Automated Sphygmomanometers. ANSI/AAMI Standard SP10-192, ed. Arlington, VA, USA, 1993.
- E. O’Brien, J. Petrie, W. Littler, M. De Swiet, P. L. Padfield, D. Altman, M. Bland, A. Coats, N. Atkins, et al., “The british hypertension society protocol for the evaluation of blood pressure measuring devices,” J hypertens, vol. 11, no. Suppl 2, pp. S43–S62, 1993.
- A. Chakraborty, D. Goswami, J. Mukhopadhyay, and S. Chakrabarti, “Measurement of arterial blood pressure through single-site acquisition of photoplethysmograph signal,” IEEE Transactions on Instrumentation and Measurement, vol. 70, pp. 1–10, 2021.
- J. Liu, Y.-T. Zhang, X.-R. Ding, W.-X. Dai, and N. Zhao, “A preliminary study on multi-wavelength ppg based pulse transit time detection for cuffless blood pressure measurement,” in 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp. 615–618, 2016.
- C.-S. Kim, A. M. Carek, O. T. Inan, R. Mukkamala, and J.-O. Hahn, “Ballistocardiogram-based approach to cuffless blood pressure monitoring: Proof of concept and potential challenges,” IEEE Transactions on Biomedical Engineering, vol. 65, no. 11, pp. 2384–2391, 2018.
- T. H. Huynh, R. Jafari, and W.-Y. Chung, “Noninvasive cuffless blood pressure estimation using pulse transit time and impedance plethysmography,” IEEE Transactions on Biomedical Engineering, vol. 66, no. 4, pp. 967–976, 2019.
- X. F. Teng and Y. T. Zhang, “An evaluation of a ptt-based method for noninvasive and cuffless estimation of arterial blood pressure,” in 2006 International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 6049–6052, 2006.
- P. A. Shaltis, A. T. Reisner, and H. H. Asada, “Cuffless blood pressure monitoring using hydrostatic pressure changes,” IEEE Transactions on Biomedical Engineering, vol. 55, no. 6, pp. 1775–1777, 2008.
- A. Tazarv and M. Levorato, “A deep learning approach to predict blood pressure from ppg signals,” in 2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), pp. 5658–5662, 2021.
- H. Mou and J. Yu, “Cnn-lstm prediction method for blood pressure based on pulse wave,” Electronics, vol. 10, no. 14, p. 1664, 2021.
- A. Paviglianiti, V. Randazzo, E. Pasero, and A. Vallan, “Noninvasive arterial blood pressure estimation using abpnet and vital-ecg,” in 2020 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), pp. 1–5, IEEE, 2020.
- E. Brophy, M. De Vos, G. Boylan, and T. Ward, “Estimation of continuous blood pressure from ppg via a federated learning approach,” Sensors, vol. 21, no. 18, p. 6311, 2021.
- S. Shimazaki, H. Kawanaka, H. Ishikawa, K. Inoue, and K. Oguri, “Cuffless blood pressure estimation from only the waveform of photoplethysmography using cnn,” in 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp. 5042–5045, 2019.
- U. Senturk, I. Yucedag, and K. Polat, “Cuff-less continuous blood pressure estimation from electrocardiogram(ecg) and photoplethysmography (ppg) signals with artificial neural network,” in 2018 26th Signal Processing and Communications Applications Conference (SIU), pp. 1–4, 2018.
- M. Kachuee, M. Kiani, H. Mohammadzade, and M. Shabany, “Cuff-Less Blood Pressure Estimation.” UCI Machine Learning Repository, 2015. DOI: https://doi.org/10.24432/C5B602.
- Muhammad Ahmad Tahir (1 paper)
- Ahsan Mehmood (10 papers)
- Muhammad Mahboob Ur Rahman (26 papers)
- Muhammad Wasim Nawaz (5 papers)
- Kashif Riaz (5 papers)
- Qammer H. Abbasi (41 papers)