MassChroQ: A versatile tool for mass spectrometry quantification (1109.5488v1)

Published 26 Sep 2011 in q-bio.QM and cs.CE

Abstract: Recently, many software tools have been developed to perform quantification in LC-MS analyses. However, most of them are specific to either a quantification strategy (e.g. label-free or isotopic labelling) or a mass-spectrometry system (e.g. high or low resolution). In this context, we have developed MassChroQ, a versatile software that performs LC-MS data alignment and peptide quantification by peak area integration on extracted ion chromatograms. MassChroQ is suitable for quantification with or without labelling and is not limited to high resolution systems. Peptides of interest (for example all the identified peptides) can be determined automatically or manually by providing targeted m/z and retention time values. It can handle large experiments that include protein or peptide fractionation (as SDS-PAGE, 2D-LC). It is fully configurable. Every processing step is traceable, the produced data are in open standard format and its modularity allows easy integration into proteomic pipelines. The output results are ready for use in statistical analyses. Evaluation of MassChroQ on complex label-free data obtained from low and high resolution mass spectrometers showed low CVs for technical reproducibility (1.4%) and high coefficients of correlation to protein quantity (0.98). MassChroQ is freely available under the GNU General Public Licence v3.0 at http://pappso.inra.fr/bioinfo/masschroq/.

Citations (263)

Summary

  • The paper introduces MassChroQ, a versatile software tool designed for quantifying LC-MS data across different mass spectrometer resolutions and labeling strategies.
  • MassChroQ uses XIC-based quantification and advanced signal processing, including baseline correction and alignment methods, to accurately quantify peptides even without prior identification.
  • Evaluated on complex data, MassChroQ demonstrated high technical reproducibility (1.4% CV) and correlation to protein quantity (0.98), proving its precision and reliability for diverse proteomic workflows.

An Expert Overview of the Versatile MassChroQ Tool for LC-MS Quantification

The paper entitled "MassChroQ: A versatile tool for mass spectrometry quantification" presents a comprehensive exploration of MassChroQ, a robust software devised for quantifying LC-MS data. The exigency for such a versatile tool is underscored within the landscape of proteomic analysis, characterized by growing data complexity and the proliferation of varied quantitative mass spectrometry methodologies.

MassChroQ is heralded for its adaptability, primarily due to its capability to perform alignment and quantification irrespective of the resolution of the mass spectrometry system—be it high resolution (HR) or low resolution (LR)—and independent of the quantification strategy, such as label-free or isotopic labeling strategies. This functionality is gained through the use of eXtracted Ion Chromatograms (XICs), allowing MassChroQ to quantify peptides by peak area integration, making it suitable for large and complex experiments inclusive of protein or peptide fractionation.

The technical evaluation of MassChroQ is notably rigorous, involving the analysis of complex label-free data from both low and high-resolution mass spectrometers. The tool demonstrated impressive performance with low coefficients of variation (CVs) for technical reproducibility (1.4%) and high correlation coefficients to protein quantity (0.98). These metrics are indicative of high precision and reliability, a testament to the tool's efficacy in diverse experimental contexts. The tool's architecture allows it to be fully configurable and its data outputs are compatible with statistical analysis packages, promoting seamless integration into existing proteomic pipelines.

A series of critical features underpin MassChroQ's functionality:

  • Peptide Quantification: MassChroQ supports both automatic and manual peptide determination processes, enabling the tool to effectively quantify peptides even in the absence of identification within certain samples.
  • Peak Detection and Correction: Through advanced signal processing—employing techniques such as baseline correction and morphological operations—MassChroQ effectively refines XICs to detect and accurately delineate peak boundaries for quantification.
  • Alignment and Matching: Recognizing potential chromatographic deviations across LC-MS runs, MassChroQ offers two alignment methods: OBI-Warp and an in-house MS/MS alignment, ensuring robust peak matching post-alignment.

The implications of this work are multilayered. Practically, MassChroQ facilitates high-throughput and precise proteomic analysis across a breadth of experimental designs, including those that utilize LR systems often considered less optimal for complex samples. Theoretically, MassChroQ's framework could inspire further developments in quantitative methodologies to accommodate emerging experimental needs, such as SRM data analyses and enhanced visualization capabilities.

Future developments are anticipated to extend MassChroQ's functionality further, potentially incorporating support for emerging mass spectrometry techniques and optimizing computational efficiency—a nod to the continuing evolution and demands of the proteomics field.

In summary, MassChroQ represents a notable advancement in mass spectrometry quantification software, balancing a high degree of technical rigor with practical versatility. This equips proteomic researchers with a powerful tool to address current and future challenges in the analysis of complex biological data.