Papers
Topics
Authors
Recent
Gemini 2.5 Flash
Gemini 2.5 Flash
133 tokens/sec
GPT-4o
7 tokens/sec
Gemini 2.5 Pro Pro
46 tokens/sec
o3 Pro
4 tokens/sec
GPT-4.1 Pro
38 tokens/sec
DeepSeek R1 via Azure Pro
28 tokens/sec
2000 character limit reached

The new Cold Neutron Chopper Spectrometer at the Spallation Neutron Source - Design and Performance (1109.1482v1)

Published 7 Sep 2011 in physics.ins-det, cond-mat.mtrl-sci, cond-mat.str-el, and cond-mat.supr-con

Abstract: The design and performance of the new Cold Neutron Chopper Spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge are described. CNCS is a direct geometry inelastic time-of-flight spectrometer, designed to cover essentially the same energy and momentum transfer ranges as IN5 at ILL, LET at ISIS, DCS at NIST, TOFTOF at FRM2, AMATERAS at J-PARC, PHAROS at LANSCE and NEAT at HZB, at similar energy resolution. Measured values of key figures such as neutron flux at sample position and energy resolution are compared between measurements and ray tracing Monte Carlo simulations, and good agreement (better than 20% of absolute numbers) has been achieved. The instrument performs very well in the cold and thermal neutron energy ranges, and promises to become a workhorse for the neutron scattering community for quasielastic and inelastic scattering experiments.

Citations (220)

Summary

  • The paper introduces a multi-chopper design that offers adjustable energy resolution (1.2%–10%) validated by both simulations and empirical measurements.
  • It demonstrates strong consistency, with neutron intensity and resolution agreeing within 20% between Monte Carlo simulations and experimental data at a peak flux near 10 meV.
  • It underscores the instrument’s versatility in high-resolution and high-flux modes, enabling diverse applications from studying spin waves to examining diffusive processes.

Design and Performance of the Cold Neutron Chopper Spectrometer at SNS

The paper details the design and performance evaluation of the Cold Neutron Chopper Spectrometer (CNCS) at the Spallation Neutron Source (SNS) in Oak Ridge. This instrument is a direct geometry inelastic time-of-flight spectrometer, designed to operate primarily in the cold and thermal neutron energy ranges, making it comparable to similar instruments across major neutron sources globally, such as IN5 at ILL, LET at ISIS, and others.

Instrument Configuration and Specifications

The CNCS is set up to optimize energy and momentum transfer resolution at low incident neutron energies between 1 and 50 meV. The configuration includes a multi-chopper system featuring four choppers: a pulse-shaping Fermi chopper operating at up to 300 Hz, disk choppers for frame overlap removal, and a high-speed sample chopper placed near the sample position. The chopper arrangement allows for adjustable energy resolution, with values ranging from approximately 1.2% to 10% of the incident energy.

The neutron guide begins 1 meter from the moderator surface and extends 34.95 meters, incorporating a curvature to minimize high-energy background. Two high-efficiency choppers perform beam shaping, while optimized guide geometry ensures maximum neutron flux at the sample position. The guide incorporates supermirror coatings transitioning from m=2.5m=2.5 to m=4m=4, ensuring high reflectivity along the beam path.

Instrument Performance

The performance evaluation illustrates remarkable consistency between ray tracing Monte Carlo simulations and empirical measurements, showing better than 20% agreement for neutron intensity and energy resolution. The well-characterized instrument performance was exemplified using a vanadium standard, which confirmed both the flux and resolution capabilities over a broad energy range. Notably, the instrument yields a peak neutron flux around 10 meV, indicative of its efficiency in both cold and thermal regimes.

The CNCS permits versatile operational settings, typically categorized into "high resolution" (HR) and "high flux" (HF) modes, catering to specific experimental needs. For instance, at an incident energy of 3 meV, the HR mode provides an energy resolution of approximately 42 μeV, while HF mode delivers higher flux with slightly relaxed resolution.

Scientific and Technological Implications

The CNCS has rapidly become an essential tool for exploring inelastic and quasielastic neutron scattering phenomena. The instrument supports varied research applications, ranging from the paper of spin waves and phonons in single crystals to investigations of diffusive processes in complex materials. Its capability to handle bulk sample equipment and to operate with user-defined configurations makes it highly adaptable to changing experimental demands.

Prospects for Future Developments

Looking ahead, the primary enhancements anticipated for the CNCS involve reducing instrument background noise and expanding operational flexibility, especially in handling sophisticated sample environments. Continuous improvements and innovations in detector technologies and data acquisition systems are expected to further enhance CNCS's utility and efficacy for cutting-edge neutron scattering research.

In conclusion, the CNCS stands out for its design sophistication and performance efficiency, proven through extensive experimental validation and simulation alignment. It continues to support crucial scientific inquiries, facilitating a deeper understanding of material properties at the atomic level.